HydraFW CAN guide
This guide is updated towards firmware release HydraFW v0.11 and later
Bus: CAN
Connections: two pins (RX/TX) and ground.
Output types: 3.3volt normal output, or open drain
(pull-up/pull-down resistors integrated in MCU or external).
Pull-up resistors: required for open collector output mode (2K – 10K).
Maximum Voltage: 5.5volts (5volt safe).
For hardware shield supported see https://github.com/smillier/HydraLINCAN
-
show
Show CAN parameters orshow pins
Show pins used in this mode -
device
with parameter1
or2
to choose CAN device (1 or 2) -
speed
with integer bitrate value (supportk
,m
suffix or no suffix)- speed up to 2Mb/s
-
id
with value specifies the frame identifier to be set -
ts1
with value specifies the Time sequence 1 value -
ts2
with value specifies the Time sequence 2 value -
sjw
with value specifies the resynchronization jump width value -
filter
Add a filter (see below) -
slcan
switch to LAWICEL/SLCAN mode -
exit
to exit CAN mode
Note default value for device 1 or 2:
For device 1 (CAN1):
> can device 1
Device: CAN1
Speed: 500000 bps
For device 2 (CAN2):
> can device 2
Device: CAN2
Speed: 500000 bps
Since 32d53fccb5352b246aea4d71cf46990a83b7bc16, it is possible to use a mask filter.
The mask filter is a bitwise AND applied to a reference value. Every frame matching the mask will be captured by the CAN interface. All others will be dropped.
A filter can be set using the filter
submenu.
-
on
enables the current filter -
off
disables the current filter -
id
sets the value to be tested -
mask
sets the bitmask to be applied
The current filter values can be displayed using the show filter
command.
CAN bus operation depend on timing parameters which determine the accuracy of the bus sampling, but also when the node (Hydrabus) must send the ACK bit. Wrong settings in the timing parameters can lead to a bus malfunction and perturbate all other nodes on the bus.
To mitigate the impact on the bus, the CAN mode initially starts in silent mode, which allows to read frames but does not send ACK bit. As soon as the first frame must be sent, the controller is set to normal mode for the rest of the session.
To get more information about CAN bus timings, please see https://vector.com/portal/medien/cmc/application_notes/AN-AND-1-106_Basic_CAN_Bit_Timing.pdf
Hardware Informations:
can1> show pins
TX: PB9
RX: PB8
can2> show pins
TX: PB13
RX: PB12
For writing, all data is split by 8 bytes (max frame data size). for example, writing ten bytes will result in sending a frame with the first eight bytes and a second with the last two bytes.
hd
command is not supported
Since da84d5085a6307558bb004a9232f140f6e7b05a7, it is also possible to write packets using the LAWICEL/SLCAN format :
txxxyzz...
Send a standard CAN frame using xxx
as ID, y
as data length and zz
as data
Txxxxxxxxyzz...
Send a standard CAN frame using xxx
as extended ID, y
as data length and zz
as data
rxxxyzz...
Send a RTR CAN frame using xxx
as ID, y
as data length and zz
as data
Rxxxxxxxxyzz...
Send a RTR CAN frame using xxx
as extended ID, y
as data length and zz
as data
Example :
t1230
Sends a standard CAN frame with 0x123
as ID and no data length
T12345678411223344
Sends a standard CAN frame with extended ID of 0x12345678
, with 4 bytes of data of value 0x11223344
If the value cannot be interpreted as a valid LAWICEL command, the data will be sent as an ASCII string in CAN frames
TBD
To be used with a real CAN bus, a CAN transceiver must be used. See HydraLINCAN shield : https://github.com/smillier/HydraLINCAN
Before to select CAN Device to use (and init the CAN Bus) the CAN Bus shall be connected with the target CAN Bus else the init will returns bsp_can_init() error 3 which means HAL_TIMEOUT because no transceiver is connected or maybe there is a bus fault.
For more details on CAN bus see: https://en.wikipedia.org/wiki/CAN_bus
- CHANGELOG
- Console commands
- Binary mode guide
-
NFC/HydraNFC v1 guide
- Read UID of an ISO/IEC_14443 Tag
- Read UID and data of a MIFARE Ultralight Tag
- Read UID of an ISO/IEC 15693 Tag
- Emul ISO14443a Tag
- Emul MIFARE Ultralight Tag
- Emul Mifare Classic Tag
- Unique NFC sniffer design
- Launch NFC sniffer from console
- Sniffer ISO14443A wireshark pcap
- Autonomous/stand-alone sniffer mode
- Sniffer ISO14443A real-time infinite trace mode
- HydraFW-HydraNFC-v1.x-TRF7970A-Tutorial