16 changes: 8 additions & 8 deletions src/derivatives/ephys.md
Original file line number Diff line number Diff line change
Expand Up @@ -5,16 +5,16 @@ This includes minimally processed data, but excludes data that has undergone ext

## Minimally processed electrophysiological data

A minimally processed EEG, MEG or iEEG data can be stored as a derivative, using the same file formats as specified for raw EEG, MEG, or iEEG.
Examples for this are MaxFiltered MEG data, or re-referenced and bandpass-filtered EEG data.
A minimally processed EEG, MEG or iEEG data can be stored as a derivative using the same file formats as specified for raw EEG, MEG, or iEEG.
Examples of this are MaxFiltered MEG data or re-referenced and bandpass-filtered EEG data.
Certain file formats that are allowed in BIDS for raw data have limited representation to some extent,
for example the EDF and BDF formats cannot be used to store epoched (or "segmented") data in a standardized way,
whereas the BrainVision and FIF file formats can.
for example, the EDF and BDF formats cannot be used to store epoched (or "segmented") data in a standardized way,
whereas the EEGLAB .set, the BrainVision Core Data Format 1.0 and the FIF file formats can.
These limitations should be taken into account when writing derivative data back to disk.
The representation of the data MUST follow the general derivative conventions and the Common file level metadata fields,
The representation of the data MUST follow the general derivative conventions and the Common file-level metadata fields,
notably the use of the [`desc` entity](../appendices/entities.md#desc).

If minimally processed data is the result from processing a BIDS dataset, then it MUST be marked as a derivative and the source data must be specified.
If minimally processed data is the result of processing a BIDS dataset, then it MUST be marked as a derivative dataset in the dataset_description.json file, and the source data must be specified.
The processing steps MUST be indicated in the [`desc` entity](../appendices/entities.md#desc),
where the label is a description identifier that distinguishes it from the original raw data.

Expand All @@ -26,12 +26,12 @@ the [`desc` entity](../appendices/entities.md#desc) is not needed to distinguish

The description of the processing in the derivative MUST be clarified in the [descriptions.tsv](common-data-types.md#descriptions-tsv) file,
with at least two columns for desc_id and the actual description.
Other columns MAY be added but are at this moment not standardized.
Other columns MAY be added but are, at this moment, not standardized.
The [descriptions.tsv](common-data-types.md#descriptions-tsv) file SHOULD include sufficient information to document the details of the data processing that resulted in the derivative.

The `_eeg.json`, `_meg.json`, or `_ieeg.json` sidecar files MUST be replicated alongside the respective derivative `_eeg.<ext>`, `_meg.<ext>`, or `_ieeg.<ext>` data files,
so that they can be processed as if it were a raw BIDS dataset.
The json sidecar file must be compliant with those for raw data and SHOULD NOT include fields that are specific to the processing that was done on the data.
The JSON sidecar file must be compliant with those for raw data and SHOULD NOT include fields that are specific to the processing that was done on the data.

## MaxFiltered MEG data