Skip to content

Commit

Permalink
deploy: db5e28e
Browse files Browse the repository at this point in the history
  • Loading branch information
MatthewSteen committed Dec 18, 2023
1 parent 5d42413 commit ba5ab4e
Show file tree
Hide file tree
Showing 15 changed files with 26,834 additions and 26,244 deletions.
Binary file added _images/g36-4.1.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
26 changes: 26 additions & 0 deletions _sources/examples/guideline36-2021-4.1.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,26 @@
# Guideline 36 - VAV Cooling Only

Model of ASHRAE Guideline 36's "VAV Cooling Only" system configuration described in section 4.1 of the document
and illustrated in Figure A-1.

![](../_static/images/g36-4.1.png)

## Downloads

- <a href="/guideline36-2021-4.1.ttl">Turtle file</a>
- <a href="/guideline36-2021-4.1.jsonld">JSON-LD file</a>

## Model Components
| Parent Class | Class | Instances |
|------------|-------|----------------|
| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Actuator](https://explore.open223.info/s223/Actuator.html) | 1 |
| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Damper](https://explore.open223.info/s223/Damper.html) | 1 |
| [Equipment](https://explore.open223.info/s223/Equipment.html) | [Sensor](https://explore.open223.info/s223/Sensor.html) | 1 |
| [Equipment](https://explore.open223.info/s223/Equipment.html) | [SingleDuctTerminal](https://explore.open223.info/s223/SingleDuctTerminal.html) | 1 |
| [Connection](https://explore.open223.info/s223/Connection.html) | [Duct](https://explore.open223.info/s223/Duct.html) | 2 |
| [ConnectionPoint](https://explore.open223.info/s223/ConnectionPoint.html) | [OutletConnectionPoint](https://explore.open223.info/s223/OutletConnectionPoint.html) | 2 |
| [ConnectionPoint](https://explore.open223.info/s223/ConnectionPoint.html) | [InletConnectionPoint](https://explore.open223.info/s223/InletConnectionPoint.html) | 2 |
| [Property](https://explore.open223.info/s223/Property.html) | [QuantifiableProperty](https://explore.open223.info/s223/QuantifiableProperty.html) | 6 |
| [Property](https://explore.open223.info/s223/Property.html) | [QuantifiableObservableProperty](https://explore.open223.info/s223/QuantifiableObservableProperty.html) | 2 |
| [Property](https://explore.open223.info/s223/Property.html) | [QuantifiableActuatableProperty](https://explore.open223.info/s223/QuantifiableActuatableProperty.html) | 1 |

7 changes: 4 additions & 3 deletions examples/NREL-example.html
Original file line number Diff line number Diff line change
Expand Up @@ -65,7 +65,7 @@
<script>DOCUMENTATION_OPTIONS.pagename = 'examples/NREL-example';</script>
<link rel="index" title="Index" href="../genindex.html" />
<link rel="search" title="Search" href="../search.html" />
<link rel="next" title="ASHRAE Guideline 36-2021 4.2 VAV Terminal with Reheat" href="guideline36-2021-4.2.html" />
<link rel="next" title="Guideline 36 - VAV Cooling Only" href="guideline36-2021-4.1.html" />
<link rel="prev" title="LBNL Example Building" href="lbnl-example.html" />
<meta name="viewport" content="width=device-width, initial-scale=1"/>
<meta name="docsearch:language" content="en"/>
Expand Down Expand Up @@ -169,6 +169,7 @@
</ul>
<p aria-level="2" class="caption" role="heading"><span class="caption-text">Example Systems</span></p>
<ul class="nav bd-sidenav">
<li class="toctree-l1"><a class="reference internal" href="guideline36-2021-4.1.html">Guideline 36 - VAV Cooling Only</a></li>
<li class="toctree-l1"><a class="reference internal" href="guideline36-2021-4.2.html">ASHRAE Guideline 36-2021 4.2 VAV Terminal with Reheat</a></li>
</ul>

Expand Down Expand Up @@ -551,11 +552,11 @@ <h2>Model Components<a class="headerlink" href="#model-components" title="Permal
</div>
</a>
<a class="right-next"
href="guideline36-2021-4.2.html"
href="guideline36-2021-4.1.html"
title="next page">
<div class="prev-next-info">
<p class="prev-next-subtitle">next</p>
<p class="prev-next-title">ASHRAE Guideline 36-2021 4.2 VAV Terminal with Reheat</p>
<p class="prev-next-title">Guideline 36 - VAV Cooling Only</p>
</div>
<i class="fa-solid fa-angle-right"></i>
</a>
Expand Down
Loading

0 comments on commit ba5ab4e

Please sign in to comment.