Skip to content

Commit

Permalink
- build 1.0.8
Browse files Browse the repository at this point in the history
- set timeout to 10sec
- added docu for additional REST Sensor
  • Loading branch information
marq24 committed Oct 26, 2023
1 parent 9298e08 commit 659f26e
Show file tree
Hide file tree
Showing 3 changed files with 170 additions and 29 deletions.
189 changes: 164 additions & 25 deletions README.md
Original file line number Diff line number Diff line change
@@ -1,35 +1,41 @@
# Tibber Pulse LOCAL

If you like to access the data of your Tibber Pulse directly (instead via the detour through the cloud), then there is
a simple approach to read the data directly from the Tibber Pulse Bridge. There are alternative solutions via an
additional MQTT - but why should the data go through such a proxy, if it can be read directly.

## Tibber Invitation link

If you want to join Tibber (become a customer), you might consider using my personal invitation link. When you use this
link, Tibber will we grant you and me a Bonus of 50,-€ for each of us, that then can be used in the Tibber store (not
for your power bill) - e.g. to but a Tibber Bridge. I am fully aware, that when you are here in this repository the
chances are very high, that you are already a Tibber customer and have already a Tibber Pulse. But I was asked by a user
if I could provide my link - so I do:
for your power bill) - e.g. to buy a Tibber Bridge. I am fully aware, that when you are here in this repository the
chances are very high, that you are already a Tibber customer and have already a Tibber Pulse.

[My personal Tibber invitation link](https://invite.tibber.com/6o0kqvzf)
If you are a customer and have not used an invitation link yet, you can also enter one afterward in the Tibber App.

[My personal Tibber invitation link](https://invite.tibber.com/6o0kqvzf) or Enter the Code: 6o0kqvzf (six, oscar, zero,
kilo, quebec, victor, zulu, foxtrot) in the App - TIA!

## Know Issues

- No Logo/Icons (Tibber) for the integration (yet)

- The Tibber Pulse Bridge supporting different communication modes (when fetching data from electricity meter). Here
I need your help! Obviously I have one electricity meter here at home. This meter is communicating via a protocol
called SML 1.04 and this is currently the __only__ one that is supported/implemented.
I need your help! Obviously I have one electricity meter here at home. This meter is communicating via a protocol
called SML 1.04 and this is currently the __only__ one that is supported/implemented.

The Tibber Bridge supporting also the modes: AutoScanMode, IEC-62056.21, Logarex and Impressions (Blinks / kwh) using
ambient or IR sensors. In order to support these other modes I would need sample data from you. If your Tibber Pulse
using one of these communications protocols, please be so kind and create here an issue in github - TIA!

- Sometimes the Pulse deliver a data-package that does not contain valid data (looks like the build in webserver have a
response buffer issue?). These invalid packages can't be read with the [python SML-Lib](https://github.com/spacemanspiff2007/SmlLib)
response buffer issue?). These invalid packages can't be read with
the [python SML-Lib](https://github.com/spacemanspiff2007/SmlLib)
and you will find then in the HA-log some `Bytes missing...` or `CRC while parse data...` messages. (when logging on
INFO Level)

If they happen the code will just try to load the data again for one time. Together with the message the actual payload

If they happen the code will just try to load the data again for one time. Together with the message the actual
payload
(data that has been read from the Tibber Pulse Bridge) will also be logged. So you can verify that the data is indeed
invalid.

Expand All @@ -38,7 +44,7 @@ if I could provide my link - so I do:
- [@spacemanspiff2007](https://github.com/spacemanspiff2007) for providing a Python SML lib that makes reading the
data from the Pulse almost effortless for a python noob like me
- [@ProfDrYoMan](https://github.com/ProfDrYoMan) for providing the initial idea. I failed to setup the ESP32 stuff, so
I took the approach writing this custom integration
I took the approach writing this custom integration

## Preparation: Enabling the web frontend of the Tibber Pulse Bridge [*Required*]

Expand All @@ -47,6 +53,7 @@ frontend for the first time you need to start the Tibber Pulse Bridge in AccessP
following steps:

### 1. Start AP-Mode

* Unplug the Tibber bridge.
* After three seconds, plug the Tibber bridge.
* After three seconds, unplug the Tibber bridge.
Expand All @@ -55,6 +62,7 @@ following steps:
The LED on the Tibber bridge should now light up green and not light blue anymore.

If this is not the case, then try this alternative:

* Unplug the Tibber bridge.
* Plug the Tibber bridge
* When the bridge light in __yellow__ then unplug the bridge again
Expand All @@ -64,7 +72,7 @@ NOW the LED on the Tibber bridge should now light up green and not light blue an

### 2. Connect to the Pulse Bridge WiFi AccessPoint

Now use any device (laptop, tablet, phone) to connect to the `Tibber Bridge` WiFi network. The password for the WiFi
Now use any device (laptop, tablet, phone) to connect to the `Tibber Bridge` WiFi network. The password for the WiFi
is the nine characters printed on the Tibber bridge - it's important to include the dash. The password should have the
pattern like this example one: `AD56-54BA`.

Expand All @@ -83,28 +91,30 @@ After setting and saving the value, remember to press *"Store params to flash"*

__Please do not modify and other values in the params__

### 4. Bring your Pulse & Bridge back to normal operation
### 4. Bring your Pulse & Bridge back to normal operation

Unplug the Tibber bridge, wait __ten seconds__ and plug it back again. Now it should connect back to your previously
configured WiFi and should work as before (submit the data to Tibber) - the LED should light up light blue again.

### 5. Final testing [do not continue if you did not completed this final step]

After you have successfully reset the Tibber bridge (AP mode is OFF and you are back in normal operation mode). Since you
After you have successfully reset the Tibber bridge (AP mode is OFF and you are back in normal operation mode). Since
you
have set the `webserver_force_enable` to `true` the web frontend should now be still accessible via the following URL:
<http://tibber_bridge/>.
<http://tibber-host/> or <http://tibber-bridge/>.

If the hostname 'tibber-bridge' is not going to work for you in your LAN, you might like to check the IP-Address of your
Tibber Pulse Bridge in your Router. __The IP *is not* the `10.133.70.1` any longer!__
If the hostname 'tibber-host' (or 'tibber-bridge') is not going to work for you in your LAN, you might like to check the
IP-Address of your Tibber Pulse Bridge in your Router. __The IP *is not* the `10.133.70.1` any longer!__

Personally I have configured my router in a way, that the Pulse Bridge gets allways the same IP assigned. I just can
recommend to do the same.
recommend to do the same. Since accessing the device via IP (instead of the host name) will save you DNS-Lookups.

When you open the web frontend of the bridge, you have to provide the user `admin` and the password always.

![img|160x90](images/web-frontend.png)

Now (when the frontend works for you) all is prepared, so you can install and use this `Tibber Local Polling` integration
Now (when the frontend works for you) all is prepared, so you can install and use this `Tibber Local Polling`
integration

## Installation

Expand All @@ -120,7 +130,8 @@ Now (when the frontend works for you) all is prepared, so you can install and us

### Manual

- Copy all files from `custom_components/tibber_local/` to `custom_components/tibber_local/` inside your config Home Assistant
- Copy all files from `custom_components/tibber_local/` to `custom_components/tibber_local/` inside your config Home
Assistant
directory.
- Restart Home Assistant to install all dependencies

Expand All @@ -136,8 +147,136 @@ Add custom integration using the web interface and follow instruction on screen.

- Go to `Configuration -> Integrations` and add "Tibber Pulse Local" integration
- Specify:
- Provide display name for the device
- Provide the address (hostname or IP) of the Pulse Bridge
- Provide the password of the Pulse Bridge
- Provide the update interval (can be 2 Seconds)
- Provide area where the Tibber Pule Bridge is located
- Provide display name for the device
- Provide the address (hostname or IP) of the Pulse Bridge
- Provide the password of the Pulse Bridge
- Provide the update interval (can be 2 Seconds)
- Provide area where the Tibber Pule Bridge is located

## Additional entities to get status information about your Tibber Pulse itself

Beside the data that the Tibber Pulse is reading from your electricity meter, the device is also provide additional
information about its own status. Since the assumption is that you want to read this additional status information with
a much lower update-interval (less frequent) the usage of a REST-Entity template a (IMHO) simple way to archive your
goal.

### REST-Template in your HA configuration.yaml

requesting `http://admin:[BRIDGE_PASSWORD]@http://[YOUR_IP]/metrics.json?node_id=1` will return a json like this one
here

```json
{
"$type": "node_status",
"node_status": {
"product_id": 49344,
"bootloader_version": 17563650,
"meter_mode": 3,
"node_battery_voltage": 3.127,
"node_temperature": 22.51,
"node_avg_rssi": -72.746,
"node_avg_lqi": 186.438,
"radio_tx_power": 190,
"node_uptime_ms": 167656940,
"meter_msg_count_sent": 75,
"meter_pkg_count_sent": 237,
"time_in_em0_ms": 8405,
"time_in_em1_ms": 30,
"time_in_em2_ms": 291717,
"acmp_rx_autolevel_300": 146,
"acmp_rx_autolevel_9600": 164
},
"hub_attachments": {
"meter_pkg_count_recv": 237,
"meter_reading_count_recv": 75,
"node_version": "1007-56bd9fb9"
}
}
```

Check if you have already a `sensor` section in your `configuration.yaml` file - if there is none - create one on as top
level entry like this (the line ' - platforms: ...' must (obviously) be replaced with the complete sections shown
further below):

```yaml
sensor:
- platform: ...
```
Add in the `sensor` section of your `configuration.yaml` file the following content:
sections with `[ CHANGE_ME:xxx ]` have to be modified to your requirements. E.g. assuming your assuming password
is __55AA-CC21__, then you have to replace `[ CHANGE_ME:YOUR-PWD ]` with just `55AA-CC21`

```yaml
- platform: rest
name: [ CHANGE_ME:Tibber Prices ]
unique_id: [ CHANGE_ME:tibber_prices ]
resource: http://admin:[ CHANGE_ME:YOUR-PWD ]@http://[ CHANGE_ME:YOUR_IP ]/metrics.json?node_id=1
method: GET
json_attributes_path: "node_status"
json_attributes:
- node_temperature
- node_avg_rssi
- radio_tx_power
- [ CHANGE_ME: add/remove as many of the node_status attributes you want to meassure/do not need ]
value_template: "{{ value_json.node_status.node_battery_voltage | float }}"
# the scan_interval will be specified in seconds...
# for update every 5min use 300 (60sec * 5min = 300sec)
# for update every 15min use 900 (60sec * 15min = 900sec)
# for update every 1h use 3600 (60sec * 60min = 3600sec)
# for update every 24h use 86400 (60sec * 60min * 24h = 86400sec)
scan_interval: 900
headers:
Content-Type: application/json
User-Agent: REST
unit_of_measurement: [ CHANGE_ME:A_UNIT_HERE ]
```

Here is a complete example assuming the password is __55AA-CC21__ the IP is __192.168.2.213__, and you want to capture
the __node_battery_voltage__ as main entity information and all other children of the `node_status` as additional
attributes of the entity that will be requested every 5 minutes:

```yaml
- platform: rest
name: Tibber Pulse Metrics
unique_id: tibber_pulse_metrics
resource: http://admin:55AA-CC21@http://192.168.2.213/metrics.json?node_id=1
method: GET
json_attributes_path: "node_status"
json_attributes:
- node_temperature
- node_avg_rssi
- node_avg_lqi
- radio_tx_power
- node_uptime_ms
- meter_msg_count_sent
- meter_pkg_count_sent
- time_in_em0_ms
- time_in_em1_ms
- time_in_em2_ms
- acmp_rx_autolevel_300
- acmp_rx_autolevel_9600
value_template: "{{ value_json.node_status.node_battery_voltage | float }}"
scan_interval: 300
headers:
Content-Type: application/json
User-Agent: REST
unit_of_measurement: V
```

Here just another example with just a single value (without additional atributes) that will update every hour (just
again have in mind, that this yaml section have to be under your `sensor` section of your `configuration.yaml` file):

```yaml
- platform: rest
name: Tibber Pulse Metrics
unique_id: tibber_pulse_metrics
resource: http://admin:55AA-CC21@http://192.168.2.213/metrics.json?node_id=1
method: GET
value_template: "{{ value_json.node_status.node_battery_voltage | float }}"
scan_interval: 3600
headers:
Content-Type: application/json
User-Agent: REST
unit_of_measurement: V
```
8 changes: 5 additions & 3 deletions custom_components/tibber_local/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -75,7 +75,8 @@ def __init__(self, hass: HomeAssistant, session, config_entry):
# initial configuration phase - so we read it from the config_entry.data ONLY!
com_mode = int(config_entry.data.get(CONF_MODE, MODE_3_SML_1_04))

self.bridge = TibberLocalBridge(host=self._host, pwd=the_pwd, websession=session, com_mode=com_mode, options=None)
self.bridge = TibberLocalBridge(host=self._host, pwd=the_pwd, websession=session, com_mode=com_mode,
options=None)
self.name = config_entry.title
self._config_entry = config_entry
super().__init__(hass, _LOGGER, name=DOMAIN, update_interval=SCAN_INTERVAL)
Expand Down Expand Up @@ -189,6 +190,7 @@ def get_as_two_digit_hex(input: int) -> str:
else:
return out;


class TibberLocalBridge:

# _communication_mode 'MODE_3_SML_1_04' is the initial implemented mode (reading binary sml data)...
Expand All @@ -215,7 +217,7 @@ async def detect_com_mode(self):
async def detect_com_mode_from_node_param27(self):
# {'param_id': 27, 'name': 'meter_mode', 'size': 1, 'type': 'uint8', 'help': '0:IEC 62056-21, 1:Count impressions', 'value': [3]}
self._com_mode = MODE_UNKNOWN
async with self.websession.get(self.url_mode, ssl=False) as res:
async with self.websession.get(self.url_mode, ssl=False, timeout=10.0) as res:
res.raise_for_status()
if res.status == 200:
json_resp = await res.json()
Expand All @@ -233,7 +235,7 @@ async def update(self):
await self.read_tibber_local(mode=self._com_mode, retry=True)

async def read_tibber_local(self, mode: int, retry: bool):
async with self.websession.get(self.url_data, ssl=False) as res:
async with self.websession.get(self.url_data, ssl=False, timeout=10.0) as res:
res.raise_for_status()
self._obis_values = {}
if res.status == 200:
Expand Down
2 changes: 1 addition & 1 deletion custom_components/tibber_local/manifest.json
Original file line number Diff line number Diff line change
Expand Up @@ -10,5 +10,5 @@
"iot_class": "local_polling",
"issue_tracker": "https://github.com/marq24/ha-tibber-pulse-local/issues",
"requirements": ["smllib==1.2"],
"version": "1.0.7"
"version": "1.0.8"
}

0 comments on commit 659f26e