Skip to content

This code example demonstrates Over-the-Air (OTA) firmware update using the AnyCloud SDK for PSoC 6 MCU and CYW43xxx connectivity devices.

License

Notifications You must be signed in to change notification settings

hcd-bdltd/mtb-example-ota-mqtt

Repository files navigation

Over-the-air firmware update using MQTT

This code example demonstrates an over-the-air (OTA) update with PSoC™ 6 or XMC7000 MCU and AIROC™ CYW43xxx Wi-Fi & Bluetooth® combo chips. The device establishes a connection with the designated MQTT broker (this example uses AWS). It periodically checks the job document to see if a new update is available. When a new update is available, it is downloaded and written to the secondary slot (flash). On the next reboot, MCUboot handles image authentication and upgrades. The upgrade can be either overwrite-based or swap-based. In an overwrite-based upgrade, the new image from the secondary slot is simply copied to the primary slot after successful validation. There is no way to revert the upgrade if the new image is inoperable. In a swap-based upgrade, images in the primary and secondary slots are swapped. The upgrade can be reverted if the new image does not confirm its operation.

MCUboot is a "secure" bootloader for 32-bit MCUs. See the README of the mtb-example-mcuboot-basic code example for more details.

OTA update middleware library enables the OTA feature. See the ota-update middleware repository on Github for more details.

The ota-update middleware can function independently and work with any bootloader, as long as the required OTA update handling storage APIs are implemented and registered with OTA agent by the user. This example enables the MCUboot support with the help of ota-bootloader-abstraction middleware. See README of the ota-bootloader-abstraction middleware for more details.

Users should build the MCUboot-based bootloader application outside of the OTA MQTT application. It is programmed separately to the device before flashing the OTA MQTT application and is not updated for the life of the device.

View this README on GitHub.

Provide feedback on this code example.

Requirements

Supported toolchains (make variable 'TOOLCHAIN')

  • GNU Arm® embedded compiler v11.3.1 (GCC_ARM) - Default value of TOOLCHAIN
  • Arm® compiler v6.16 (ARM)
  • IAR C/C++ compiler v9.30.1 (IAR)

Supported kits (make variable 'TARGET')

Hardware setup

This example uses the board's default configuration. See the kit user guide to ensure that the board is configured correctly.

Software setup

See the ModusToolbox™ tools package installation guide for information about installing and configuring the tools package.

  1. Install a terminal emulator if you don't have one. Instructions in this document use Tera Term.

  2. This code example implements a generic MQTT client that can connect to various MQTT brokers. In this document, the instructions to set up and run the MQTT client have been provided for the AWS IoT and local mosquitto MQTT brokers for reference. see section Setting up the MQTT broker for more details.

  3. Install the Python Interpreter and add it to the top of the system path in environmental variables. This code example is tested with Python v3.8.10.

Note: This code example currently does not work with the custom BSP name for the KIT_XMC72_EVK_MUR_43439M2 and CY8CPROTO-062S3-4343W kits. If you want to change the BSP name to a non-default value, ensure to update the custom BSP name in Makefile under the relevant section. The build fails, if you do not update the custom BSP name.

Structure and overview

This code example is a dual-core application, where the MCUboot-based bootloader application runs on the CM0P core and the OTA MQTT application runs on the CM4/CM7 core. The OTA MQTT application fetches the new image and places it in the secondary slot (flash), then the MCUboot takes care of updating the existing image with the new image. The mtb-example-mcuboot-basic code example is the MCUboot-based bootloader application used for this purpose.

The MCUboot-based bootloader application and this OTA MQTT application should be built and programmed independently. They must be placed separately in the workspace as you would do for any other two independent applications. For this example, only the MCUboot-based bootloader application is required. The root directory of the MCUboot-based bootloader application is referred to as <MCUboot>/<bootloader_app> and the root directory of the OTA MQTT application is referred to as <OTA_MQTT> in this document. An example workspace is as follows:

<example-workspace>
   |
   |-<MCUboot>               # MCUboot-based bootloader and blinky applications directory
   |-<OTA_MQTT>              # OTA MQTT application directory
   |-<mtb_shared>            # Shared library for both the applications
   |

You must first build and program the MCUboot-based bootloader application into the CM0P core, and this should be done only once. The OTA MQTT application can then be programmed into the CM4/CM7 core, and you need to only modify this application for all application purposes.

This README expects you to be familiar with MCUboot and its concepts. See MCUboot basics and MCUboot repository on GitHub for more information.

Using the code example

Create the project

The ModusToolbox™ tools package provides the Project Creator as both a GUI tool and a command line tool.

Use Project Creator GUI
  1. Open the Project Creator GUI tool.

    There are several ways to do this, including launching it from the dashboard or from inside the Eclipse IDE. For more details, see the Project Creator user guide (locally available at {ModusToolbox™ install directory}/tools_{version}/project-creator/docs/project-creator.pdf).

  2. On the Choose Board Support Package (BSP) page, select a kit supported by this code example. See Supported kits.

    Note: To use this code example for a kit not listed here, you may need to update the source files. If the kit does not have the required resources, the application may not work.

  3. On the Select Application page:

    a. Select the Applications(s) Root Path and the Target IDE.

    Note: Depending on how you open the Project Creator tool, these fields may be pre-selected for you.

    b. Select this code example from the list by enabling its check box.

    Note: You can narrow the list of displayed examples by typing in the filter box.

    c. (Optional) Change the suggested New Application Name and New BSP Name.

    d. Click Create to complete the application creation process.

Use Project Creator CLI

The 'project-creator-cli' tool can be used to create applications from a CLI terminal or from within batch files or shell scripts. This tool is available in the {ModusToolbox™ install directory}/tools_{version}/project-creator/ directory.

Use a CLI terminal to invoke the 'project-creator-cli' tool. On Windows, use the command-line 'modus-shell' program provided in the ModusToolbox™ installation instead of a standard Windows command-line application. This shell provides access to all ModusToolbox™ tools. You can access it by typing "modus-shell" in the search box in the Windows menu. In Linux and macOS, you can use any terminal application.

The following example clones the "mtb-example-ota-mqtt" application with the desired name "OTA_MQTT" configured for the CY8CPROTO-062S2-43439 BSP into the specified working directory, C:/mtb_projects:

project-creator-cli --board-id CY8CPROTO-062S2-43439 --app-id mtb-example-ota-mqtt --user-app-name OTA_MQTT --target-dir "C:/mtb_projects"

The 'project-creator-cli' tool has the following arguments:

Argument Description Required/optional
--board-id Defined in the field of the BSP manifest Required
--app-id Defined in the field of the CE manifest Required
--target-dir Specify the directory in which the application is to be created if you prefer not to use the default current working directory Optional
--user-app-name Specify the name of the application if you prefer to have a name other than the example's default name Optional

Note: The project-creator-cli tool uses the git clone and make getlibs commands to fetch the repository and import the required libraries. For details, see the "Project creator tools" section of the ModusToolbox™ tools package user guide (locally available at {ModusToolbox™ install directory}/docs_{version}/mtb_user_guide.pdf).

Open the project

After the project has been created, you can open it in your preferred development environment.

Eclipse IDE

If you opened the Project Creator tool from the included Eclipse IDE, the project will open in Eclipse automatically.

For more details, see the Eclipse IDE for ModusToolbox™ user guide (locally available at {ModusToolbox™ install directory}/docs_{version}/mt_ide_user_guide.pdf).

Visual Studio (VS) Code

Launch VS Code manually, and then open the generated {project-name}.code-workspace file located in the project directory.

For more details, see the Visual Studio Code for ModusToolbox™ user guide (locally available at {ModusToolbox™ install directory}/docs_{version}/mt_vscode_user_guide.pdf).

Keil µVision

Double-click the generated {project-name}.cprj file to launch the Keil µVision IDE.

For more details, see the Keil µVision for ModusToolbox™ user guide (locally available at {ModusToolbox™ install directory}/docs_{version}/mt_uvision_user_guide.pdf).

IAR Embedded Workbench

Open IAR Embedded Workbench manually, and create a new project. Then select the generated {project-name}.ipcf file located in the project directory.

For more details, see the IAR Embedded Workbench for ModusToolbox™ user guide (locally available at {ModusToolbox™ install directory}/docs_{version}/mt_iar_user_guide.pdf).

Command line

If you prefer to use the CLI, open the appropriate terminal, and navigate to the project directory. On Windows, use the command-line 'modus-shell' program; on Linux and macOS, you can use any terminal application. From there, you can run various make commands.

For more details, see the ModusToolbox™ tools package user guide (locally available at {ModusToolbox™ install directory}/docs_{version}/mtb_user_guide.pdf).

Testing flow of OTA MQTT application

Follow the flow chart as shown in Figure 1.

Figure 1. Testing flow of OTA MQTT application

Building and programming MCUboot

The mtb-example-mcuboot-basic code example bundles two applications: MCUboot-based bootloader application that runs on CM0P core, and blinky application that runs on CM4/CM7 core.

  1. Import the mtb-example-mcuboot-basic code example per the instructions in the Using the code example section of its readme.

  2. The MCUboot-based bootloader and OTA MQTT applications must have the same understanding of the memory layout. The memory layout is defined through JSON files. The OTA MQTT application provides a set of predefined JSON files that can be readily used. Both the MCUboot-based bootloader and OTA MQTT applications must use the same JSON file.

    The <OTA_MQTT>/flashmap folder contains the pre-defined flashmap JSON files. The following files are supported by this example.

    Table 1. Supported JSON files

    Target Supported JSON files
    CY8CPROTO-062S2-43439
    CY8CPROTO-062-4343W
    CY8CKIT-062S2-43012
    CY8CEVAL-062S2-LAI-4373M2
    CY8CEVAL-062S2-LAI-43439M2
    CY8CEVAL-062S2-MUR-43439M2
    CY8CEVAL-062S2-MUR-4373EM2
    CY8CEVAL-062S2-MUR-4373M2
    CY8CEVAL-062S2-CYW43022CUB
    psoc62_2m_ext_overwrite_single.json
    psoc62_2m_ext_swap_single.json
    CY8CPROTO-062S3-4343W psoc62_512k_xip_swap_single.json
    KIT_XMC72_EVK_MUR_43439M2 xmc7200_int_overwrite_single.json
    xmc7200_int_swap_single.json

    Copy the required flashmap JSON file from the <OTA_MQTT>/flashmap folder and paste it in the <MCUboot>/flashmap folder.

  3. Modify the value of the FLASH_MAP variable in the <MCUboot>/user_config.mk file to the selected JSON file name from the previous step.

  4. Connect the board to your PC using the provided USB cable through the KitProg3 USB connector.

  5. Open a CLI terminal.

    On Linux and macOS, you can use any terminal application. On Windows, open 'modus-shell' app from the Start menu.

  6. Navigate the terminal to the <mtb_shared>/mcuboot/<tag>/scripts folder.

  7. Run the following commands to ensure that the required modules are installed.

    Note: For Linux and macOS platforms, please use python3 instead of python in the below command.

    python -m pip install -r requirements.txt
    
    python -m pip install --upgrade cysecuretools==5.0.0
    

    Note: cysecuretools is used for signing the image for XMC7000 MCUs.

  8. Open a serial terminal emulator and select the KitProg3 COM port. Set the serial port parameters to 8N1 and 115200 baud.

  9. Build and program the bootloader application per the Step-by-step instructions in its README or simply follow the instruction as shown below.

    Using CLI

    From the terminal, go to <MCUboot>/bootloader_app and execute the make program_proj command to build and program the MCUboot-based bootloader application using the default toolchain to the seleted target.

    make program_proj
    

    After programming, the MCUboot starts automatically. Confirm that the UART terminal displays a message as shown in Figure 2:

    Figure 2. Booting with no bootable image

Setting up the MQTT broker

AWS IoT Core
  1. Set up the MQTT device (also known as a Thing) in the AWS IoT core as described in the Getting started with AWS IoT tutorial.

Note: While setting up your device, ensure that the policy associated with this device permits all MQTT operations (iot:Connect, iot:Publish, iot:Receive, and iot:Subscribe) for the resource used by this device. For testing purposes, it is recommended to have the following policy document which allows all MQTT Policy Actions on all Amazon Resource Names (ARNs).

{
     "Version": "2012-10-17",
     "Statement": [
         {
             "Effect": "Allow",
             "Action": "iot:*",
             "Resource": "*"
         }
     ]
}
  1. Download the following certificates and keys that are created and activated in the previous step:

    • A certificate for the AWS IoT Thing - xxxxxxxxxx.aws-client-certificate.crt
    • A private key - xxxxxxxxxx.aws-private.key or xxxxxxxxxx.aws-private.pem
    • Root CA "RSA 2048 bit key: Amazon Root CA 1" for AWS IoT from CA certificates for server authentication - xxxx.AmazonRootCA1.crt.
  2. Copy the certificates and key, paste it in the <OTA_MQTT>/scripts folder.

  3. Rename the following file names in the <OTA_MQTT>/scripts folder.

    • xxxx.AmazonRootCA1.crt to aws_ca.crt
    • xxxxxxxxxx.aws-client-certificate.crt to aws_client.crt
    • xxxxxxxxxx.aws-private.key to aws_private.key
Mosquitto local broker

This code example uses the locally installable mosquitto that runs on your computer as the default broker. You can also use one of the other public MQTT brokers listed at https://github.com/mqtt/mqtt.github.io/wiki/public_brokers.

  1. Download the executable setup from Mosquitto downloads site.

  2. Run the setup to install the software. During installation, uncheck the Service component. Also, note down the installation directory.

  3. Once the installation is complete, add the installation directory to the system Path.

  4. Open a CLI terminal.

    On Linux and macOS, you can use any terminal application. On Windows, open the 'modus-shell' app from the Start menu.

  5. Navigate to the <OTA_MQTT>/scripts folder.

  6. Execute the following command to generate self-signed SSL certificates and keys. On Linux and macOS, you can get your device local IP address by running the ifconfig command on any terminal application. On Windows, run the ipconfig command on a command prompt.

    sh generate_ssl_cert.sh <local-ip-address-of-your-pc>
    

    Example:

    sh generate_ssl_cert.sh 192.168.0.10
    

    This step will generate the following files in the same <OTA_MQTT>/scripts directory:

    1. mosquitto_ca.crt - Root CA certificate
    2. mosquitto_ca.key - Root CA private key
    3. mosquitto_server.crt - Server certificate
    4. mosquitto_server.key - Server private key
    5. mosquitto_client.crt - Client certificate
    6. mosquitto_client.key - Client private key
  7. The <OTA_MQTT>/scripts/mosquitto.conf file is preconfigured for starting the Mosquitto server for this code example. You can edit the file if you wish to make other changes to the broker settings.

  8. Starting the MQTT server:

    • Using the code example in TLS mode (default):

      1. Execute the following command:

        mosquitto -v -c mosquitto.conf
        
    • Using the code example in Non-TLS mode:

      1. Edit the <OTA Application>/scripts/mosquitto.conf file.

        1. change the value of require_certificate parameter to false.
        2. change the value of listener parameter to 1883.
      2. Execute the following command:

        mosquitto -v -c mosquitto.conf
        

Setting up the MQTT publisher script

  1. Open a CLI terminal.

    On Linux and macOS, you can use any terminal application. On Windows, open 'modus-shell' app from the Start menu.

  2. Navigate to the <OTA_MQTT>/scripts folder.

  3. Run the following command to ensure that the required Python modules are installed.

    pip install -r requirements.txt
    
  4. Edit the <OTA_MQTT>/scripts/publisher.py file to configure your MQTT publisher (MQTT server).

    1. Modify the value of the BOARD variable to your selected TARGET in the following format.

      if TARGET=APP_CY8CPROTO-062S2-43439, then BOARD = "APP_CY8CPROTO_062S2_43439"
      
      if TARGET=APP_KIT_XMC72_EVK_MUR_43439M2, then BOARD = "APP_KIT_XMC72_EVK_MUR_43439M2"
      

      For example:

      BOARD = "APP_CY8CPROTO_062S2_43439"
      

      Note: Please make sure to change the - to _ in the BOARD variable value after copied from the TARGET variable.

    2. Modify the value of the AMAZON_BROKER_ADDRESS variable to your custom endpoint on the Settings page of the AWS IoT console. This has the format ABCDEFG1234567.iot.<region>.amazonaws.com.

      Note: If you are using the local MQTT broker (e.g Mosquitto broker), then modify the value of MOSQUITTO_BROKER_LOCAL_ADDRESS to the local IP address of your MQTT broker.

    3. Ensure the value of the BROKER_ADDRESS variable is AMAZON_BROKER_ADDRESS.

      Note: If you are using the local MQTT broker (e.g Mosquitto broker), then modify the value of BROKER_ADDRESS to MOSQUITTO_BROKER_LOCAL_ADDRESS.

    4. Ensure the value of the TLS_ENABLED variable is True.

    5. Ensure the value of the BROKER_PORT variable is 8883.

      Note: If you are using the local MQTT broker (e.g Mosquitto broker), then ensure the value of BROKER_PORT variable is 8884. Currently in the publisher.py file conditional if-else block is used to automatically select a BROKER_PORT value based on the selected MQTT broker.

  5. Ensure the certificate and key file names in the <OTA_MQTT>/scripts folder and following variables value in the <OTA_MQTT>/scripts/publisher.py file are same.

    • ca_certs = "aws_ca.crt"
    • certfile = "aws_client.crt"
    • keyfile = "aws_private.key"

    The above variables are present under AMAZON BROKER section at the last in the <OTA_MQTT>/scripts/publisher.py file.

    Note: If you are using the local MQTT broker (e.g Mosquitto broker), then ensure the certificate and key file names in the <OTA_MQTT>/scripts folder and above variables value in the <OTA_MQTT>/scripts/publisher.py file under MOSQUITTO_BROKER_LOCAL_ADDRESS section are same. Currently in the publisher.py file conditional if-else block is used to automatically select a default certificate and key file names based on the selected MQTT broker.

  6. Run the publisher.py Python script.

    The scripts take arguments such as kit name, broker URL, and file path. For details on the supported arguments and their usage, execute the following command:

    Note: For Linux and macOS platforms, please use python3 instead of python in the below command.

    python publisher.py --help
    

    To start the publisher script for the default settings of this example, execute the following command:

    python publisher.py tls
    

    After starting the publisher, the publisher will connect to the broker and subscribe to the topic as shown in Figure 3.

    Figure 3. Publisher connected to the broker and subscribed to the topic

Operation

  1. Connect the board to your PC using the provided USB cable through the KitProg3 USB connector.

  2. Open a terminal program and select the KitProg3 COM port. Set the serial port parameters to 8N1 and 115200 baud.

  3. Modify the PLATFORM variable in the <OTA_MQTT>/Makefile based on the target you have selected. Currently in the Makefile a conditional if-else block is used to automatically select a value based on the target selected. You can remove it and directly assign a value as per Table 2.

    Table 2: Target-specific platform values

    Target PLATFORM value
    CY8CPROTO-062S2-43439
    CY8CPROTO-062-4343W
    CY8CKIT-062S2-43012
    CY8CEVAL-062S2-LAI-4373M2
    CY8CEVAL-062S2-LAI-43439M2
    CY8CEVAL-062S2-MUR-43439M2
    CY8CEVAL-062S2-MUR-4373EM2
    CY8CEVAL-062S2-MUR-4373M2
    CY8CEVAL-062S2-CYW43022CUB
    PSOC_062_2M
    CY8CPROTO-062S3-4343W PSOC_062_512K
    KIT_XMC72_EVK_MUR_43439M2 XMC7200

  4. Modify the OTA_FLASH_MAP variable in the <OTA_MQTT>/Makefile to change the JSON file name to match the selection made while programming the MCUboot-based bootloader application. Currently in the Makefile, a conditional if-else block is used to automatically select a default flash map file based on the target selected. You can remove it and directly assign the required flash map file to the OTA_FLASH_MAP variable.

    The <OTA_MQTT>/flashmap folder contains the pre-defined flashmap JSON files. The following files are supported by this example.

    Table 3: Supported JSON files

    Target Supported JSON files
    CY8CPROTO-062S2-43439
    CY8CPROTO-062-4343W
    CY8CKIT-062S2-43012
    CY8CEVAL-062S2-LAI-4373M2
    CY8CEVAL-062S2-LAI-43439M2
    CY8CEVAL-062S2-MUR-43439M2
    CY8CEVAL-062S2-MUR-4373EM2
    CY8CEVAL-062S2-MUR-4373M2
    CY8CEVAL-062S2-CYW43022CUB
    psoc62_2m_ext_overwrite_single.json
    psoc62_2m_ext_swap_single.json
    CY8CPROTO-062S3-4343W psoc62_512k_xip_swap_single.json
    KIT_XMC72_EVK_MUR_43439M2 xmc7200_int_overwrite_single.json
    xmc7200_int_swap_single.json

    Note: Both the MCUboot-based bootloader and OTA MQTT applications must use the same JSON file.

  5. Edit the <OTA_MQTT>/configs/ota_app_config.h file to configure your OTA MQTT application:

    1. Modify the connection configuration such as WIFI_SSID, WIFI_PASSWORD, and WIFI_SECURITY macros to match the settings of your Wi-Fi network.

      Note: If you are using the local MQTT broker (e.g Mosquitto broker), then make sure that the device running the MQTT local broker and the kit are connected to the same network.

    2. Modify the value of the MQTT_BROKER_URL macro to your custom endpoint on the Settings page of the AWS IoT console. This has the format ABCDEFG1234567.iot.<region>.amazonaws.com.

      Note: If you are using the local MQTT broker (e.g Mosquitto broker), then modify the value of MQTT_BROKER_URL to the local IP address of your MQTT broker.

    3. Ensure the value of the MQTT_SERVER_PORT macro is 8883.

      Note: If you are using the local MQTT broker (e.g Mosquitto broker), then modify the value of MQTT_SERVER_PORT to 8884. if the code example has been configured to work in non-TLS mode: Set the value of MQTT_SERVER_PORT to 1883.

    4. By default, this code example works in TLS mode. To use the example in non-TLS mode, modify ENABLE_TLS to false and skip the next step of adding the certificate.

    5. Add the certificates and key:

      1. Open a CLI terminal.

        On Linux and macOS, you can use any terminal application. On Windows, open 'modus-shell' app from the Start menu.

      2. Navigate the terminal to <OTA_MQTT>/scripts directory.

      3. Run the format_cert_key.py Python script to generate the string format of the certificate and key files that can be added as a macro. Pass the name of the certificate or key with the extension as an argument to the Python script:

        Note: For Linux and macOS platforms, please use python3 instead of python in the below command.

        python format_cert_key.py <one-or-more-file-name-of-certificate-or-key-with-extension>
        

        For example:

        python format_cert_key.py aws_ca.crt aws_client.crt aws_private.key
        

        You can either convert the values to strings by running the format_cert_key.py scripts like shown above or you can use the HTML utility available here to convert the certificates and keys from PEM format to C string format. You need to clone the repository from GitHub to use the utility.

      4. Copy the generated strings and add it to the ROOT_CA_CERTIFICATE, CLIENT_CERTIFICATE and CLIENT_KEY macros per the sample shown.

  6. Edit the job document (<OTA_MQTT>/scripts/ota_update.json):

    1. Modify the value of Broker to match the value of the MQTT_BROKER_URL variable, MQTT_BROKER_URL variable present in the <OTA_MQTT>/configs/ota_app_config.h file.

    2. Modify the value of the variable Board to your selected TARGET in the following format.

      if TARGET=APP_CY8CPROTO-062S2-43439, then Board:"APP_CY8CPROTO_062S2_43439"
      
      if TARGET=APP_KIT_XMC72_EVK_MUR_43439M2, then Board:"APP_KIT_XMC72_EVK_MUR_43439M2"
      

      For example:

        "Board":"APP_CY8CPROTO_062S2_43439",
      

      Note: Please make sure to change the - to _ in the Board variable value while coping from the TARGET variable.

    3. Ensure the value of the Port macro is 8883.

      Note: If you are using the local MQTT broker (e.g Mosquitto broker), then modify the value of Port to 8884. if the code example has been configured to work in non-TLS mode: Set the value of Port to 1883.

  7. Program the board using one of the following:

    Using Eclipse IDE for ModusToolbox™
    1. Select the application project in the Project Explorer.

    2. In the Quick Panel, scroll down, and click <Application Name> Program (KitProg3_MiniProg4).

    Using CLI

    From the terminal, execute the make program command to build and program the application using the default toolchain to the default target. The default toolchain is specified in the application's Makefile but you can override those values manually:

    make program TOOLCHAIN=<toolchain>
    

    For example:

    make program TOOLCHAIN=GCC_ARM
    

    After programming, MCUboot will validate the primary image. After successfully validating the primary image, MCUboot let the CM4/CM7 core run the image from the primary slot. Observe that the user LED blinks at a one second interval. Observe the messages on the UART terminal and wait for the device to make the required connections. Once the MQTT client (device) is connected to the broker, it will download the job document (ota_update.json) as shown in Figure 5.

    Figure 4 shows the logs of publisher while publishing the job document.

    Figure 4. Publishing the job document

    Figure 5. Connection to the MQTT broker and downloaded the job document

  8. The job document (ota_update.json) placed in the <OTA_MQTT>/scripts folder has value of Version as 1.0.0. The OTA update will not happen, because the OTA MQTT application version and available update version are the same.

  9. Modify the value of the BLINKY_DELAY_MS macro to (100) in the <OTA_MQTT>/source/led_task.c file and change the application version in the <OTA_MQTT>/Makefile by setting APP_VERSION_MINOR to 1.

  10. Build the application (DO NOT program it to the kit). This new image will be published to the MQTT broker in the following steps to demonstrate the OTA update.

    Using Eclipse IDE for ModusToolbox™
    1. Select the application project in the Project Explorer.

    2. In the Quick Panel, scroll down, and click Build <Application Name> Application.

    Using CLI
    1. From the terminal, execute the make build command to build the application using the default toolchain to the default target. You can specify a toolchain manually:
      make build TOOLCHAIN=<toolchain>
      
      For example:
      make build TOOLCHAIN=GCC_ARM
      
  11. After a successful build, edit the <OTA_MQTT>/scripts/ota_update.json file to modify the value of Version to 1.1.0.

  12. The OTA MQTT application now finds and downloads the updated job document, and now the available update version is higher than the OTA MQTT application version. So, the OTA MQTT application starts to download the new image as shown in Figure 7 and places it in the secondary slot. Once the download is completed, a soft reset is issued. Then the MCUboot starts the image upgrade process (swapping the images between the primary and secondary slots, after successfully validating the secondary image).

    Figure 6 shows the logs of publisher while publishing the new image.

    Figure 6. Publishing the new image

    Figure 7. Image download

  13. After the image upgrade is successfully completed, MCUboot lets the CM4/CM7 core run the new image from the primary slot. Observe that the user LED is now blinking at a 100-millisecond interval and The UART terminal displays the message as shown in Figure 8.

    Figure 8. Updated to new image

  14. To test the revert feature of MCUboot, send a bad image as v1.2.0 OTA update. The bad image used in this example is an infinite loop. The watchdog timer will reset the bad image and upon reboot, MCUboot will revert the primary image back to v1.1.0 good image. Edit <OTA_MQTT>/Makefile and add TEST_REVERT to the Defines variable as shown:

    DEFINES+=TEST_REVERT
    

    Note: In an overwrite-based upgrade, the secondary image is simply copied to the primary slot after successful validation. There is no way to revert the upgrade if the secondary image is inoperable. TEST_REVERT feature is not applicable for overwrite-based upgrade.

    See the MCUboot basics of the mtb-example-mcuboot-basic code example for more details about the overwrite-based and swap-based upgrades.

  15. Edit the application version in the <OTA_MQTT>/Makefile by setting APP_VERSION_MINOR to 2.

  16. Build the application per Step 10.

  17. After a successful build, edit the <OTA_MQTT>/scripts/ota_update.json file to modify the value of Version to 1.2.0.

  18. The OTA MQTT application will now find this new v1.2.0 image and update to it. After the update, within a few seconds, the watchdog timer resets the devices. Upon reset, MCUboot reverts to the v1.1.0 good image. The UART terminal displays the message as shown in Figure 9.

    Figure 9. Reverting to good image

Note: After completing the last step, the device will be running the v1.1.0 good image and the publisher will still be hosting the v1.2.0 bad image. Because the version of the image hosted by the publisher is greater than the version of the image on the device, the device will re-download the v1.2.0 bad image. This causes an infinite upgrade and reverts the cycle. To avoid this scenario, stop the publisher script after you test the code example. In a production environment, the application is responsible for blacklisting bad image versions and to avoid upgrading to them in the future.

Debugging

You can debug the example to step through the code. In the IDE, use the <Application Name> Debug (KitProg3_MiniProg4) configuration in Quick Panel. For details, see the "Program and debug" section in the Eclipse IDE for ModusToolbox™ user guide.

Note: (Only while debugging) On the CM4 CPU, some code in main() may execute before the debugger halts at the beginning of main(). This means that some codes executes twice - once before the debugger stops execution, and again after the debugger resets the program counter to the beginning of main(). See KBA231071 to learn about this and for the workaround.

Design and implementation

Figure 10 shows the flow of the OTA update process using MQTT. The application which needs OTA updates should run the OTA agent. The OTA agent spawns threads to receive OTA updates when available, without intervening with the application's core functionality.

The initial application resides in the primary slot of the flash. When the OTA agent receives an update, the new image is placed in the secondary slot of the flash. On the next reboot, MCUboot copies the image from the secondary slot into the primary slot and then CM4 or CM7 will run the upgraded image from the primary slot.

Figure 10. Overview of OTA update using MQTT

For more details on the features and configurations offered by the ota-update library, see its README.

Both MCUboot-based bootloader and user applications must have an identical understanding of the memory layout, otherwise, the MCUboot may consider an authentic image as invalid.

For more details on the features and configurations of MCUboot-based bootloader, see the Design and implementation of MCUboot.

This example implements two RTOS tasks: OTA client and LED blinky. Both these tasks are independent and do not communicate with each other. The OTA client task initializes the dependent middleware and starts the OTA agent. The LED task blinks the user LED at a specified delay.

All the source files related to the two tasks are placed under the <OTA_MQTT>/source folder:

Table 4: Source files related to OTA client and LED blinky

File Description
ota_task.c Contains the task and functions related to the OTA client.
ota_task.h Contains the public interfaces for the OTA client task.
led_task.c Contains the task and functions related to LED blinking.
led_task.h Contains the public interfaces for the LED blink task.
main.c Initializes the BSP and the retarget-io library, and creates the OTA client and LED blink tasks.
heap_usage Contains the code for printing heap usage.

All the scripts and configurations needed for this example are placed under the <OTA_MQTT>/scripts folder:

Table 5: Scripts and confIguration files for OTA update over MQTT

File Description
publisher.py Python script to communicate with the client and to publish the OTA images.
ota_update.json OTA job document.
format_cert_key.py Python script to convert certificate/key to string format.
mosquitto.conf Preconfigured file for starting the Mosquitto server.
generate_ssl_cert.sh Shell script to generate the required self-signed CA, server, and client certificates.

The <OTA_MQTT>/configs folder contains other configurations related to the OTA middleware, FreeRTOS, and MBEDTLS.

Table 6: Application configuration files

File Description
ota_app_config.h Contains the OTA and Wi-Fi configuration macros such as SSID, password, MQTT broker details, certificates, and key.
cy_ota_config.h Contains the OTA middleware level configuration macros.
mbedtls_user_config.h Contains the mbedtls configuration macros.
COMPONENT_CM7/FreeRTOSConfig.h Contains the FreeRTOS configuration macros for XMC7000 family.
COMPONENT_CM4/FreeRTOSConfig.h Contains the FreeRTOS configuration macros for PSoC6™ family.
COMPONENT_MCUBOOT/flash/cy_ota_flash.c Contains OTA flash operation APIs.
COMPONENT_MCUBOOT/flash/COMPONENT_OTA_PSOC_062/flash_qspi.c Contains QSPI flash related APIs.
COMPONENT_MCUBOOT/flash/COMPONENT_OTA_PSOC_062/flash_qspi.h Contains the declaration of QSPI flash related APIs.

Security

The MCUboot-based bootloader application enables image authentication feature of MCUboot library. MCUboot verifies the signature of the image in the primary slot every time before booting. In addition, it verifies the signature of the image in the secondary slot before copying it to the primary slot. When these options are enabled, the public key (cypress-test-ec-p256.pub) is embedded within the MCUboot-based bootloader application. The OTA MQTT application is signed using the private key (cypress-test-ec-p256.pem) during the post-build steps, the ota-bootloader-abstraction library is taken care the image signing for the OTA MQTT application.

the MCUboot-based bootloader application includes a sample public key (cypress-test-ec-p256.pub) under the <MCUboot>/keys directory and the OTA MQTT application includes a sample private key (cypress-test-ec-p256.pem) under the <mtb_shared>/ota-bootloader-abstraction/<tag>/scripts/mcuboot/keys directory. Both the <MCUboot>/keys and <mtb_shared>/ota-bootloader-abstraction/<tag>/scripts/mcuboot/keys directories must have the same pair of keys. Otherwise image (primary/secondary) validation fails, MCUboot-based bootloader application will prints a message "MCUBoot Bootloader found none of bootable images".

You must not use this key pair in your end product. See Generating a key pair for generating a new key pair. Once you generated the key pair, copy the keys to the both <MCUboot>/keys and <mtb_shared>/ota-bootloader-abstraction/<tag>/scripts/mcuboot/keys directories.

Note: See Security to learn more about the image authentication feature of MCUboot.


Resources and settings

Table 7. Application resources

Resource Alias/object Purpose
UART (HAL) cy_retarget_io_uart_obj UART HAL object used by Retarget-IO for the Debug UART port
GPIO (HAL) CYBSP_USER_LED User LED

Related resources

Resources Links
Application notes AN228571 – Getting started with PSoC™ 6 MCU on ModusToolbox™
AN215656 – PSoC™ 6 MCU: Dual-CPU system design
AN234334 – Getting started with XMC7000 MCU on ModusToolbox™
AN234023 – Smart IO usage setup in XMC7000 family
Code examples Using ModusToolbox™ on GitHub
Device documentation PSoC™ 6 MCU datasheets
PSoC™ 6 technical reference manuals
XMC7000 MCU datasheets
XMC7000 reference manuals
Development kits Select your kits from the Evaluation board finder
XMC™ eval boards
Libraries on GitHub mtb-pdl-cat1 – PSoC™ 6 Peripheral Driver Library (PDL)
mtb-hal-cat1 – Hardware Abstraction Layer (HAL) library
Middleware on GitHub psoc6-middleware – Links to all PSoC™ 6 MCU middleware
mcu-middleware – Links to all MCU middleware
MCUboot – Open-source library enabling the development of secure bootloader applications for 32-bit MCUs
retarget-io – Utility library to retarget STDIO messages to a UART port
ota-update – OTA library and docs
wifi-mw-core – Wi-Fi middleware core library and docs
ota-bootloader-abstraction - OTA MCUboot-based bootloader abstraction
mqtt – MQTT library and docs
Tools ModusToolbox™ – ModusToolbox™ software is a collection of easy-to-use libraries and tools enabling rapid development with Infineon MCUs for applications ranging from wireless and cloud-connected systems, edge AI/ML, embedded sense and control, to wired USB connectivity using PSoC™ Industrial/IoT MCUs, AIROC™ Wi-Fi and Bluetooth® connectivity devices, XMC™ Industrial MCUs, and EZ-USB™/EZ-PD™ wired connectivity controllers. ModusToolbox™ incorporates a comprehensive set of BSPs, HAL, libraries, configuration tools, and provides support for industry-standard IDEs to fast-track your embedded application development.

Other resources

Infineon provides a wealth of data at www.infineon.com to help you select the right device, and quickly and effectively integrate it into your design.

For XMC™ MCU devices, see 32-bit XMC™ Industrial microcontroller based on Arm® Cortex®-M.

Document history

Document title: CE230031Over-the-air firmware update using MQTT

Version Description of change
1.0.0 New code example
1.1.0 Minor Makefile updates to sync with BSP changes
1.2.0 Updated the .cyignore file to support new build system changes
2.0.0 Updated to support OTA v2.x and ModusToolbox™ v2.2
This version is not backward compatible with ModusToolbox™ v2.1
2.1.0 Minor update to README - Added steps to install required Python modules
2.2.0 Updated the configuration file to support MbedTLS v2.22.0
3.0.0 Update to:
1. Support ota v4.X library
2. Use locally installed Mosquitto broker
3. Support swap upgrade with MCUboot
3.1.0 Added support for the kit CY8CEVAL-062S2-LAI-4373M2
4.0.0 Updated to support ModusToolbox™ v2.4 and BSP v3.X
Added support for CY8CEVAL-062S2-MUR-43439M2 kit
5.0.0 Updated the example to use the new ota-update v1.0.0 library
6.0.0 Updated the example to use ota-update v1.1.0 library
Updated to support ModusToolbox™ v3.0
Added support for CY8CPROTO-062S3-4343W kit
6.1.0 Added support for CY8CEVAL-062S2-CYW43022CUB
Updated to support ModusToolbox™ v3.2
7.0.0 Updated to support OTA update middleware v4.0.0
Added support for KIT_XMC72_EVK_MUR_43439M2, CY8CEVAL-062S2-LAI-43439M2, CY8CEVAL-062S2-MUR-4373EM2, CY8CEVAL-062S2-MUR-4373M2 and CY8CPROTO-062S2-43439 kits

All referenced product or service names and trademarks are the property of their respective owners.

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc., and any use of such marks by Infineon is under license.


© Cypress Semiconductor Corporation, 2020-2024. This document is the property of Cypress Semiconductor Corporation, an Infineon Technologies company, and its affiliates ("Cypress"). This document, including any software or firmware included or referenced in this document ("Software"), is owned by Cypress under the intellectual property laws and treaties of the United States and other countries worldwide. Cypress reserves all rights under such laws and treaties and does not, except as specifically stated in this paragraph, grant any license under its patents, copyrights, trademarks, or other intellectual property rights. If the Software is not accompanied by a license agreement and you do not otherwise have a written agreement with Cypress governing the use of the Software, then Cypress hereby grants you a personal, non-exclusive, nontransferable license (without the right to sublicense) (1) under its copyright rights in the Software (a) for Software provided in source code form, to modify and reproduce the Software solely for use with Cypress hardware products, only internally within your organization, and (b) to distribute the Software in binary code form externally to end users (either directly or indirectly through resellers and distributors), solely for use on Cypress hardware product units, and (2) under those claims of Cypress's patents that are infringed by the Software (as provided by Cypress, unmodified) to make, use, distribute, and import the Software solely for use with Cypress hardware products. Any other use, reproduction, modification, translation, or compilation of the Software is prohibited.
TO THE EXTENT PERMITTED BY APPLICABLE LAW, CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS DOCUMENT OR ANY SOFTWARE OR ACCOMPANYING HARDWARE, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. No computing device can be absolutely secure. Therefore, despite security measures implemented in Cypress hardware or software products, Cypress shall have no liability arising out of any security breach, such as unauthorized access to or use of a Cypress product. CYPRESS DOES NOT REPRESENT, WARRANT, OR GUARANTEE THAT CYPRESS PRODUCTS, OR SYSTEMS CREATED USING CYPRESS PRODUCTS, WILL BE FREE FROM CORRUPTION, ATTACK, VIRUSES, INTERFERENCE, HACKING, DATA LOSS OR THEFT, OR OTHER SECURITY INTRUSION (collectively, "Security Breach"). Cypress disclaims any liability relating to any Security Breach, and you shall and hereby do release Cypress from any claim, damage, or other liability arising from any Security Breach. In addition, the products described in these materials may contain design defects or errors known as errata which may cause the product to deviate from published specifications. To the extent permitted by applicable law, Cypress reserves the right to make changes to this document without further notice. Cypress does not assume any liability arising out of the application or use of any product or circuit described in this document. Any information provided in this document, including any sample design information or programming code, is provided only for reference purposes. It is the responsibility of the user of this document to properly design, program, and test the functionality and safety of any application made of this information and any resulting product. "High-Risk Device" means any device or system whose failure could cause personal injury, death, or property damage. Examples of High-Risk Devices are weapons, nuclear installations, surgical implants, and other medical devices. "Critical Component" means any component of a High-Risk Device whose failure to perform can be reasonably expected to cause, directly or indirectly, the failure of the High-Risk Device, or to affect its safety or effectiveness. Cypress is not liable, in whole or in part, and you shall and hereby do release Cypress from any claim, damage, or other liability arising from any use of a Cypress product as a Critical Component in a High-Risk Device. You shall indemnify and hold Cypress, including its affiliates, and its directors, officers, employees, agents, distributors, and assigns harmless from and against all claims, costs, damages, and expenses, arising out of any claim, including claims for product liability, personal injury or death, or property damage arising from any use of a Cypress product as a Critical Component in a High-Risk Device. Cypress products are not intended or authorized for use as a Critical Component in any High-Risk Device except to the limited extent that (i) Cypress's published data sheet for the product explicitly states Cypress has qualified the product for use in a specific High-Risk Device, or (ii) Cypress has given you advance written authorization to use the product as a Critical Component in the specific High-Risk Device and you have signed a separate indemnification agreement.
Cypress, the Cypress logo, and combinations thereof, ModusToolbox, PSoC, CAPSENSE, EZ-USB, F-RAM, and TRAVEO are trademarks or registered trademarks of Cypress or a subsidiary of Cypress in the United States or in other countries. For a more complete list of Cypress trademarks, visit www.infineon.com. Other names and brands may be claimed as property of their respective owners.

About

This code example demonstrates Over-the-Air (OTA) firmware update using the AnyCloud SDK for PSoC 6 MCU and CYW43xxx connectivity devices.

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published