Expand Up @@ -304,7 +304,7 @@ CRDs should be configured during replication prepare stage with repctl as descri
But make sure to align to the same namespace during the whole installation.
3. Edit `samples/secret/secret.yaml` file and configure connection information for your PowerStore arrays changing following parameters:
- *endpoint*: defines the full URL path to the PowerStore API.
- *globalID*: specifies what storage cluster the driver should use
- *globalID*: specifies what storage cluster the driver should use.
- *username*, *password*: defines credentials for connecting to array.
- *skipCertificateValidation*: defines if we should use insecure connection or not.
- *isDefault*: defines if we should treat the current array as a default.
Expand Down
198 changes: 164 additions & 34 deletions content/v1/deployment/csmoperator/drivers/powerstore.md
Original file line number Diff line number Diff line change
Expand Up @@ -13,27 +13,47 @@ To deploy the Operator, follow the instructions available [here](../../#installa
Note that the deployment of the driver using the operator does not use any Helm charts and the installation and configuration parameters will be slightly different from the one specified via the Helm installer.

### Check existing ContainerStorageModule CRD

User can query for all Dell CSI drivers using the following command:

```bash
kubectl get csm --all-namespaces
```


### Prerequisites

The following are requirements to be met before installing the CSI Driver for Dell PowerStore:
- A Kubernetes or OpenShift cluster (see [supported versions](../../../../csidriver/#features-and-capabilities))
- If you plan to use either the Fibre Channel, iSCSI, NVMe/TCP, or NVMe/FC protocols, refer to either _Fibre Channel requirements_ or _Set up the iSCSI Initiator_ or _Set up the NVMe Initiator_ sections below. You can use NFS volumes without FC, iSCSI, NVMe/TCP, or NVMe/FC configurations.
> You can use either the Fibre Channel (FC), iSCSI, NVMe/TCP, or NVMe/FC protocol, but you do not need all four to be enabled.
> For NVMe support the preferred multipath solution is NVMe native multipathing. The [Dell Host Connectivity Guide](https://elabnavigator.dell.com/vault/pdf/Linux.pdf?key=1725374107988) describes the details of each configuration option.
> If you want to use pre-configured iSCSI/FC hosts be sure to check that they are not part of any host group.
- Linux native multipathing requirements
- Mount propagation is enabled on container runtime that is being used
- If using Snapshot feature, satisfy all Volume Snapshot requirements
- Insecure registries are defined in Docker or other container runtimes, for CSI drivers that are hosted in a non-secure location.
- Ensure that your nodes support mounting NFS volumes if using NFS


#### Fibre Channel requirements

Dell PowerStore supports Fibre Channel communication. If you use the Fibre Channel protocol, ensure that the
following requirement is met before you install the CSI Driver for Dell PowerStore:
- Zoning of the Host Bus Adapters (HBAs) to the Fibre Channel port must be done.

- Zoning of the Host Bus Adapters (HBAs) to the Fibre Channel port must be done.

#### Set up the iSCSI Initiator

The CSI Driver for Dell PowerStore v1.4 and higher supports iSCSI connectivity.

If you use the iSCSI protocol, set up the iSCSI initiators as follows:

- Ensure that the iSCSI initiators are available on both Controller and Worker nodes.
- Kubernetes nodes must have access (network connectivity) to an iSCSI port on the Dell PowerStore array that

- Kubernetes nodes must have network connectivity to an iSCSI port on the Dell PowerStore array that
has IP interfaces. Manually create IP routes for each node that connects to the Dell PowerStore.
- All Kubernetes nodes must have the _iscsi-initiator-utils_ package for CentOS/RHEL or _open-iscsi_ package for Ubuntu installed, and the _iscsid_ service must be enabled and running.
To do this, run the `systemctl enable --now iscsid` command.
Expand All @@ -42,15 +62,110 @@ To do this, run the `systemctl enable --now iscsid` command.
For information about configuring iSCSI, see _Dell PowerStore documentation_ on Dell Support.


#### Set up the NVMe Initiator
### Set up the NVMe Initiator

The following requirements must be fulfilled in order to successfully use the NVMe protocols with the CSI PowerStore driver:

- All OpenShift or Kubernetes nodes connecting to Dell storage arrays must use unique NQNs.
- The driver requires the NVMe command-line interface (nvme-cli) to manage the NVMe client and target. The nvme-cli utility provides a command-line and interactive shell option. The NVMe CLI tool is installed in the host using the below command on RPM oriented Linux distributions.

```bash
sudo dnf -y install nvme-cli
```

- Support for NVMe requires native NVMe multipathing to be configured on each worker node in the cluster. Please refer to the [Dell Host Connectivity Guide](https://elabnavigator.dell.com/vault/pdf/Linux.pdf?key=1725374107988) for more details on NVMe connectivity requirements. To determine if the worker nodes are configured for native NVMe multipathing run the following command on each worker node:

```bash
cat /sys/module/nvme_core/parameters/multipath
```

>If the result of the command displays Y then NVMe native multipathing is enabled in the kernel. If the output is N then native NVMe multipating is disabled. Consult the [Dell Host Connectivity Guide](https://elabnavigator.dell.com/vault/pdf/Linux.pdf?key=1725374107988) for Linux to enable native NVMe multipathing.
- The default NVMeTCP native multipathing policy is "numa". The preferred IO policy for NVMe devices used for PowerStore is round-robin. You can use udev rules to enable the round robin policy on all worker nodes. To view the IO policy you can use the following command:

```bash
nvme list-subsys
```

**Configure the IO policy**

To change the IO policy to round-robin you can add a udev rule on each worker node. Place a config file in /etc/udev/rules.d with the name 71-nvme-io-policy.rules with the following contents:

```text
ACTION=="add|change", SUBSYSTEM=="nvme-subsystem", ATTR{iopolicy}="round-robin"
```

In order to change the rules on a running kernel you can run the following commands:

If you want to use the protocol, set up the NVMe initiators as follows:
- The driver requires NVMe management command-line interface (nvme-cli) to use configure, edit, view or start the NVMe client and target. The nvme-cli utility provides a command-line and interactive shell option. The NVMe CLI tool is installed in the host using the below command.
```bash
sudo apt install nvme-cli
/sbin/udevadm control --reload-rules
/sbin/udevadm trigger --type=devices --action=change
```

On OCP clusters you can add a MachineConfig to enable this rule on all worker nodes:

```yaml
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: 99-workers-multipath-round-robin
labels:
machineconfiguration.openshift.io/role: worker
spec:
config:
ignition:
version: 3.2.0
storage:
files:
- contents:
source: data:text/plain;charset=utf-8;base64,QUNUSU9OPT0iYWRkfGNoYW5nZSIsIFNVQlNZU1RFTT09Im52bWUtc3Vic3lzdGVtIiwgQVRUUntpb3BvbGljeX09InJvdW5kLXJvYmluIg==
verification: {}
filesystem: root
mode: 420
path: /etc/udev/rules.d/71-nvme-io-policy.rules
```
**Configure the control loss timeout**
To reduce the impact of PowerStore non disruptive software upgrades you must set the control loss timeout. This can be done using udev rules on each worker node. More information can be found in the [Dell Host Connectivity Guide](https://elabnavigator.dell.com/vault/pdf/Linux.pdf?key=1725374107988). The configure the control loss timeout place a config file in /etc/udev/rules.d with the name 72-nvmf-ctrl_loss_tmo.rules with the following contents:
```text
ACTION=="add|change", SUBSYSTEM=="nvme", KERNEL=="nvme*", ATTR{ctrl_loss_tmo}="-1"
```
In order to change the rules on a running kernel you can run the following commands:

```bash
/sbin/udevadm control --reload-rules
/sbin/udevadm trigger --type=devices --action=change
```

On OCP clusters you can add a MachineConfig to enable this rule on all worker nodes:

```yaml
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
metadata:
name: 99-nvmf-ctrl-loss-tmo
labels:
machineconfiguration.openshift.io/role: worker
spec:
config:
ignition:
version: 3.2.0
storage:
files:
- contents:
source: data:text/plain;charset=utf-8;base64,QUNUSU9OPT0iYWRkfGNoYW5nZSIsIFNVQlNZU1RFTT09Im52bWUiLCBLRVJORUw9PSJudm1lKiIsIEFUVFJ7Y3RybF9sb3NzX3Rtb309Ii0xIgo=
verification: {}
filesystem: root
mode: 420
path: /etc/udev/rules.d/72-nvmf-ctrl_loss_tmo.rules
```
**Requirements for NVMeTCP**
> Starting with OCP 4.14 NVMe/TCP is enabled by default on RCOS nodes.
- Modules including the nvme, nvme_core, nvme_fabrics, and nvme_tcp are required for using NVMe over Fabrics using TCP. Load the NVMe and NVMe-OF Modules using the below commands:
```bash
modprobe nvme
Expand All @@ -64,8 +179,11 @@ modprobe nvme_tcp
*NOTE:*
- Do not load the nvme_tcp module for NVMeFC

#### Linux multipathing requirements
Dell PowerStore supports Linux multipathing. Configure Linux multipathing before installing the CSI Driver for Dell
### Linux multipathing requirements

> For NVMe connectivity native NVMe multipathing is used. The following sections apply only for iSCSI and Fiber Channel connectivity.
Dell PowerStore supports Linux multipathing and NVMe native multipathing. Configure Linux multipathing before installing the CSI Driver for Dell
PowerStore.

Set up Linux multipathing as follows:
Expand All @@ -75,21 +193,38 @@ Set up Linux multipathing as follows:
- Enable `user_friendly_names` and `find_multipaths` in the `multipath.conf` file.
- Ensure that the multipath command for `multipath.conf` is available on all Kubernetes nodes.

##### multipathd `MachineConfig`
The following is a sample multipath.conf file:

```text
defaults {
user_friendly_names yes
find_multipaths yes
}
blacklist {
}
```

If the above command is not successful, ensure that the /etc/multipath.conf file is present and configured properly. Once the file has been configured correctly, enable the multipath service by running the following command:
`sudo systemctl enable multipathd`

Finally, you have to restart the service by providing the command
`sudo systemctl restart multipathd`

If you are installing a CSI Driver which requires the installation of the Linux native Multipath software - _multipathd_, please follow the below instructions
On OCP clusters you can add a MachineConfig to configure multipathing on the worker nodes.

To enable multipathd on RedHat CoreOS nodes you need to prepare a working configuration encoded in base64.
You will need to first base64 encode the multipath.conf and add it to the MachineConfig definition.

```bash echo 'defaults {
```bash
echo 'defaults {
user_friendly_names yes
find_multipaths yes
}
blacklist {
blacklist {
}' | base64 -w0
```

Use the base64 encoded string output in the following `MachineConfig` yaml file (under source section)

```yaml
apiVersion: machineconfiguration.openshift.io/v1
kind: MachineConfig
Expand All @@ -110,17 +245,12 @@ spec:
mode: 400
path: /etc/multipath.conf
```
After deploying this`MachineConfig` object, CoreOS will start multipath service automatically.
After deploying this`MachineConfig` object, CoreOS will start the multipath service automatically.
Alternatively, you can check the status of the multipath service by entering the following command in each worker nodes.
`sudo multipath -ll`

If the above command is not successful, ensure that the /etc/multipath.conf file is present and configured properly. Once the file has been configured correctly, enable the multipath service by running the following command:
`sudo /sbin/mpathconf –-enable --with_multipathd y`
Finally, you have to restart the service by providing the command
`sudo systemctl restart multipathd`
For additional information refer to official documentation of the multipath configuration.
For additional information refer to the [Dell Host Connectivity Guide](https://elabnavigator.dell.com/vault/pdf/Linux.pdf?key=1725374107988).

#### (Optional) Volume Snapshot Requirements
For detailed snapshot setup procedure, [click here.](../../../../snapshots/#optional-volume-snapshot-requirements)
Expand Down Expand Up @@ -157,15 +287,15 @@ CRDs should be configured during replication prepare stage with repctl as descri
nfsAcls: "0777" # (Optional) defines permissions - POSIX mode bits or NFSv4 ACLs, to be set on NFS target mount directory.
# NFSv4 ACls are supported for NFSv4 shares on NFSv4 enabled NAS servers only. POSIX ACLs are not supported and only POSIX mode bits are supported for NFSv3 shares.
```
Change the parameters with relevant values for your PowerStore array.
Change the parameters with relevant values for your PowerStore array.
Add more blocks similar to above for each PowerStore array if necessary.

If replication feature is enabled, ensure the secret includes all the PowerStore arrays involved in replication.

#### User Privileges
The username specified in `config.yaml` must be from the authentication providers of PowerStore. The user must have the correct user role to perform the actions. The minimum requirement is **Storage Operator**.

3. Create Kubernetes secret:
3. Create Kubernetes secret:

Create a file called `secret.yaml` in same folder as `config.yaml` with following content
```yaml
Expand All @@ -187,9 +317,9 @@ CRDs should be configured during replication prepare stage with repctl as descri

### Install Driver

1. Follow all the [prerequisites](#prerequisite) above
2. Create a CR (Custom Resource) for PowerStore using the sample files provided
1. Follow all the [prerequisites](#prerequisites) above

2. Create a CR (Custom Resource) for PowerStore using the sample files provided
[here](https://github.com/dell/csm-operator/tree/master/samples). This file can be modified to use custom parameters if needed.

3. Users should configure the parameters in CR. The following table lists the primary configurable parameters of the PowerStore driver and their default values:
Expand All @@ -198,10 +328,10 @@ CRDs should be configured during replication prepare stage with repctl as descri
| --------- | ----------- | -------- |-------- |
| replicas | Controls the number of controller pods you deploy. If the number of controller pods is greater than the number of available nodes, the excess pods will be in pending state until new nodes are available for scheduling. Default is 2 which allows for Controller high availability. | Yes | 2 |
| namespace | Specifies namespace where the driver will be installed | Yes | "powerstore" |
| fsGroupPolicy | Defines which FS Group policy mode to be used. Supported modes `None, File and ReadWriteOnceWithFSType` | No |"ReadWriteOnceWithFSType"|
| fsGroupPolicy | Defines which FS Group policy mode to be used. Supported modes `None, File and ReadWriteOnceWithFSType`. In OCP <= 4.16 and K8s <= 1.29, fsGroupPolicy is an immutable field. | No |"ReadWriteOnceWithFSType"|
| storageCapacity | Enable/Disable storage capacity tracking feature | No | false |
| ***Common parameters for node and controller*** |
| X_CSI_POWERSTORE_NODE_NAME_PREFIX | Prefix to add to each node registered by the CSI driver | Yes | "csi-node"
| X_CSI_POWERSTORE_NODE_NAME_PREFIX | Prefix to add to each node registered by the CSI driver | Yes | "csi-node"
| X_CSI_FC_PORTS_FILTER_FILE_PATH | To set path to the file which provides a list of WWPN which should be used by the driver for FC connection on this node | No | "/etc/fc-ports-filter" |
| ***Controller parameters*** |
| X_CSI_POWERSTORE_EXTERNAL_ACCESS | allows specifying additional entries for hostAccess of NFS volumes. Both single IP address and subnet are valid entries | No | empty |
Expand All @@ -214,16 +344,16 @@ CRDs should be configured during replication prepare stage with repctl as descri
kubectl create -f <input_sample_file.yaml>
```
This command will deploy the CSI PowerStore driver in the namespace specified in the input YAML file.
- Next, the driver should be installed, you can check the condition of driver pods by running

- Next, the driver should be installed, you can check the condition of driver pods by running
```bash
kubectl get all -n <driver-namespace>
```

5. [Verify the CSI Driver installation](../#verifying-the-driver-installation)

6. Refer https://github.com/dell/csi-powerstore/tree/main/samples for the sample files.
**Note** :

**Note** :
1. "Kubelet config dir path" is not yet configurable in case of Operator based driver installation.
2. Snapshotter and resizer sidecars are not optional. They are defaults with Driver installation.
2. Snapshotter and resizer sidecars are not optional. They are defaults with Driver installation.
Loading

0 comments on commit fa42525

Please sign in to comment.