Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Deye Hybrid Inverters Information and Firmwares #29

Open
wants to merge 13 commits into
base: main
Choose a base branch
from
Binary file added 0_5407_1/MCU1-SG-Ver0000-C369-CK.bin
Binary file not shown.
1 change: 1 addition & 0 deletions 0_5407_1/MCU1-SG-Ver0000-C369-CK.bin.DIGEST
Original file line number Diff line number Diff line change
@@ -0,0 +1 @@
5d5296252f3356bfb362fcc0d2b16ec7400b1f712f366543b94a796679497515 MCU1-SG-Ver0000-C369-CK.bin
Binary file added 0_5407_1/MCU1-SG-Ver0000-C36B-CK.bin
Binary file not shown.
Binary file added 0_5407_1/MCU1-SG-Ver0000-C36E-CK.bin
Binary file not shown.
1 change: 1 addition & 0 deletions 0_5407_1/MCU1-SG-Ver0000-C372-CK.DIGEST
Original file line number Diff line number Diff line change
@@ -0,0 +1 @@
f70fa648eb98a9997756794a7937d1217816a99ab5a6f303b3ef2f65baf925c8 MCU1-SG-Ver0000-C372-CK.bin
Binary file added 0_5407_1/MCU1-SG-Ver0000-C372-CK.bin
Binary file not shown.
Binary file added 0_5407_1/MCU2_6027US_NC_NR8K59V.bin
Binary file not shown.
Binary file added 0_5407_1/SG_5K_MCU2_V3382-NR.bin
Binary file not shown.
1 change: 1 addition & 0 deletions 0_5407_1/SG_5K_MCU2_V3382-NR.bin.DIGEST
Original file line number Diff line number Diff line change
@@ -0,0 +1 @@
235dd63aab35589fe0c3d70a2987a338d13331484d0f430f421bd330472c2633 SG_5K_MCU2_V3382-NR.bin
Binary file added 0_5407_1/SG_5K_MCU2_V3385-NR.bin
Binary file not shown.
1 change: 1 addition & 0 deletions 0_5407_1/SG_5K_MCU2_V3385-NR.bin.DIGEST
Original file line number Diff line number Diff line change
@@ -0,0 +1 @@
32ab1b7cb1c25a69c7d64991e85be7a6cd3401359a9506fe35bb8aa23f3c4589 SG_5K_MCU2_V3385-NR.bin
Binary file added 0_5407_1/SG_5K_MCU2_V3386-NR.bin
Binary file not shown.
Binary file added 0_5407_1/SG_5K_MCU2_V3387-NR.bin
Binary file not shown.
1 change: 1 addition & 0 deletions 0_5407_1/SG_5K_MCU2_V3387-NR.bin.DIGEST
Original file line number Diff line number Diff line change
@@ -0,0 +1 @@
d28f2234607300134ffc141fd116e5e7e6c8a2596fe0dd1195f42889215ffa58 SG_5K_MCU2_V3387-NR.bin
Binary file added 0_5407_1/SG_6K_MCU2_V4386-NR.bin
Binary file not shown.
51 changes: 49 additions & 2 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -50,8 +50,16 @@ http://47.254.36.66/0_D0002_18/MW3_16U_5406_2.31.bin
http://47.254.36.66/0_D0002_18/MW3_15_0501_1.21.bin
http://47.254.36.66/0_D0002_18/MW3_15_0501_1.23.bin

# Deye Hybrid Inverters
http://47.254.36.66/0_5407_18/MCU1-SG-Ver0000-C362-CK.bin
# Deye Hybrid Inverters HMI Firmware (MCU1)
http://47.254.36.66/0_5407_1/MCU1-SG-Ver0000-C362-CK.bin
http://47.254.36.66/0_5407_1/MCU1-SG-Ver0000-C36E-CK.bin
http://47.254.36.66/0_5407_1/MCU1-SG-Ver0000-C372-CK.bin

# Deye Hybrid Inverters Main Firmware (MCU2)
http://47.254.36.66/0_5407_1/SG_5K_MCU2_V3387-NR.bin (SUN-5K-SG04LP1-AU)
http://47.254.36.66/0_5407_1/SG_6K_MCU2_V4386-NR.bin (SUN-6K-SG03LP1-EU)
http://47.254.36.66/0_5407_1/MCU2_5227US_NC_NR8K59V.bin (SUN-8K-SG01LP1-??)
http://47.254.36.66/0_5407_1/MCU2_6027US_NC_NR8K59V.bin (SUN-8K-SG01LP1-??)

```

Expand Down Expand Up @@ -91,3 +99,42 @@ done
## Call for help

If you have more information or insights into the firmware update process, alternative URLs or other information let me know.


# Deye Hybrid Inverter Firmware

Deye also stores the firmware for their hybrid inverters on the same server. So far the http://47.254.36.66/0_5407_1/ directory has been identified, but there may be others.
The firmware located here has been confirmed to work on the SUN-3K-SG04LP1-AU-24V and SUN-5K-SG04LP1-AU, however based on naming conventions, it seems like this same firmware is used across a lot of the hybrid inverter models and regions.

There are two types of firmware files in there, one for the HMI (display) and the other for the main firmware.
Examples:
Main: SG_5K_MCU2_V3384-NR.bin
HMI: MCU1-SG-Ver0000-C366-CK.bin

Based on information in this forum thread: https://powerforum.co.za/topic/12655-deye-inverter-latest-firmware/
It is recomended to update the HMI first, followed by the Main firmware. Generally the HMI firmware update doesn't result in the inverter shutting down the outputs, but the Main firmware normally does.

Update Procedure :

1) Go to the IP address of the WiFi module of the inverter (stick logger), login : admin\admin
2) On the left, click the Upgrade inverter item (the inverter itself, not the Stick Logger firmware)
3) Select HMI file, i.e. MCU1-SG-Ver0000-C36E-CK.bin (MCU1 = HMI) as the first file, click upgrade. (time +/- 15 minutes)
4) After rebooting, repeat the procedure, but now select the MAIN firmware file, i.e. SG_6K_MCU2_V4386-NR.bin (MCU2 = MAIN). (time +/- 15 minutes)

FYI : the WiFi Stick Logger can also be updated by the Deye service (yet another firmware).

If you have difficulty, you may need to powercycle the inverter before beginning the process.

## Summary of HMI firmware changes (see photos here hybrid-inverter-info/HMI-photos)

C362 - C369
- Added Language 'Polish'
- 'Low Power Mode<Low Batt' moved from 'Batt Mode' screen to 'Func Set4' screen
- 'Low Noise Mode' moved from 'Batt Set2' screen to 'Func Set4' screen
- 'Grid Side INV Meter2' renamed to 'Grid Tie Meter2' on 'Paral Set3' Screen
- New setting on 'Func Set4' screen: 'Export Power Limiter' (appears to match the 'Max Sell Power' seting on 'Work Mode1' screen)
- New setting on 'Func Set4' screen: 'Import Power Limiter' (the manual says this limits power from the grid, but has a lower priority than 'Grid Peak Shaving' setting.
- New setting on 'Func Set4' screen: 'MPPT Multi-Point Scanning'
- New setting on 'Port Set1' screen: 'off grid immediately off'
- New setting on 'Port Set1' screen: 'AC couple Frz High'

Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added hybrid-inverter-info/HMI-photos/C362_Batt-48V.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added hybrid-inverter-info/HMI-photos/C362_Grid.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added hybrid-inverter-info/HMI-photos/C362_Home.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added hybrid-inverter-info/HMI-photos/C362_Info.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added hybrid-inverter-info/HMI-photos/C362_Li-BMS.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added hybrid-inverter-info/HMI-photos/C362_Load.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added hybrid-inverter-info/HMI-photos/C362_Menu.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added hybrid-inverter-info/HMI-photos/C362_Solar.jpg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added hybrid-inverter-info/HMI-photos/Updating.jpg
Binary file not shown.