-
Notifications
You must be signed in to change notification settings - Fork 93
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Add net import share custom math tests
- Loading branch information
1 parent
1e9e9f5
commit 818a0ac
Showing
5 changed files
with
240 additions
and
13 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,37 +1,44 @@ | ||
# Force upper limit on carrier imports within nodes or across all nodes as a share of all carrier flows at a node/across nodes. | ||
# Imports of transmission technologies are defined by `flow_out` (outflow from a transmission technology that originated in a remote node). | ||
|
||
constraints: | ||
net_import_share_max: | ||
description: Limit upper bound on electricity imports within nodes as a share of all electricity flows at each node. | ||
foreach: [nodes, timesteps] | ||
where: "defined(techs=ac_transmission, within=nodes, how=any)" | ||
where: "defined(techs=test_transmission_elec, within=nodes, how=any)" | ||
equations: | ||
- expression: net_import_share * sum(flow_in[techs=$transmission_techs, carriers=power], over=techs) <= $total_energy_balance | ||
- expression: net_import_share * sum(flow_out[techs=$transmission_techs, carriers=electricity], over=techs) <= $total_energy_balance | ||
sub_expressions: | ||
total_energy_balance: | ||
- expression: sum(flow_out[carriers=power], over=techs) - sum(flow_in[carriers=power], over=techs) | ||
- expression: sum(flow_out[carriers=electricity], over=techs) - sum(flow_in[carriers=electricity], over=techs) | ||
slices: | ||
transmission_techs: | ||
- expression: get_transmission_techs(ac_transmission) | ||
- expression: get_transmission_techs(test_transmission_elec) | ||
|
||
net_annual_import_share_max: | ||
description: Limit upper bound on annual electricity imports within nodes as a share of all electricity flows at each node. | ||
foreach: [nodes] | ||
where: "defined(techs=ac_transmission, within=nodes, how=any)" | ||
where: "defined(techs=test_transmission_elec, within=nodes, how=any)" | ||
equations: | ||
- expression: net_import_share * sum(flow_in[techs=$transmission_techs, carriers=power], over=[techs, timesteps]) <= $total_energy_balance | ||
- expression: net_import_share * sum(flow_out[techs=$transmission_techs, carriers=electricity], over=[techs, timesteps]) <= $total_energy_balance | ||
sub_expressions: | ||
total_energy_balance: | ||
- expression: sum(flow_out[carriers=power], over=[techs, timesteps]) - sum(flow_in[carriers=power], over=[techs, timesteps]) | ||
- expression: sum(flow_out[carriers=electricity], over=[techs, timesteps]) - sum(flow_in[carriers=electricity], over=[techs, timesteps]) | ||
slices: | ||
transmission_techs: | ||
- expression: get_transmission_techs([ac_transmission, free_transmission]) | ||
- expression: get_transmission_techs(test_transmission_elec) | ||
|
||
net_annual_import_share_max_node_group: | ||
where: "[power] in carriers" | ||
description: Limit upper bound on annual heat imports across two nodes in the model as a share of combined heat flows in both nodes. | ||
equations: | ||
- expression: net_import_share * sum(flow_in[techs=$transmission_techs, carriers=power, nodes=$node_group], over=[nodes, techs, timesteps]) <= $total_energy_balance | ||
- expression: net_import_share * sum(flow_out[techs=$transmission_techs, nodes=$node_group, carriers=$carrier], over=[nodes, techs, timesteps]) <= $total_energy_balance | ||
sub_expressions: | ||
total_energy_balance: | ||
- expression: sum(flow_out[carriers=power, nodes=$node_group], over=[nodes, techs, timesteps]) - sum(flow_in[carriers=power, nodes=$node_group], over=[nodes, techs, timesteps]) | ||
- expression: sum(flow_out[nodes=$node_group, carriers=$carrier], over=[nodes, techs, timesteps]) - sum(flow_in[nodes=$node_group, carriers=$carrier], over=[nodes, techs, timesteps]) | ||
slices: | ||
transmission_techs: | ||
- expression: get_transmission_techs(free_transmission) | ||
- expression: get_transmission_techs(test_transmission_heat) | ||
node_group: | ||
- expression: "[region1_1, region1_2, region1_3]" | ||
- expression: "[a, c]" | ||
carrier: | ||
- expression: heat |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,68 @@ | ||
\* Source Pyomo model name=None *\ | ||
|
||
min | ||
objectives(dummy_obj)(0): | ||
+2.0 ONE_VAR_CONSTANT | ||
|
||
s.t. | ||
|
||
c_u_constraints(net_annual_import_share_max)(a)_: | ||
+0.5 variables(flow_out)(a__test_transmission_elec_b__electricity__2005_01_01_00_00) | ||
+0.5 variables(flow_out)(a__test_transmission_elec_b__electricity__2005_01_01_01_00) | ||
+0.5 variables(flow_out)(a__test_transmission_elec_c__electricity__2005_01_01_00_00) | ||
+0.5 variables(flow_out)(a__test_transmission_elec_c__electricity__2005_01_01_01_00) | ||
-1 variables(flow_out)(a__test_supply_elec__electricity__2005_01_01_00_00) | ||
-1 variables(flow_out)(a__test_supply_elec__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(a__test_demand_elec__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(a__test_demand_elec__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(a__test_transmission_elec_b__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(a__test_transmission_elec_b__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(a__test_transmission_elec_c__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(a__test_transmission_elec_c__electricity__2005_01_01_01_00) | ||
<= 0.0 | ||
|
||
c_u_constraints(net_annual_import_share_max)(b)_: | ||
+0.5 variables(flow_out)(b__test_transmission_elec_a__electricity__2005_01_01_00_00) | ||
+0.5 variables(flow_out)(b__test_transmission_elec_a__electricity__2005_01_01_01_00) | ||
-1 variables(flow_out)(b__test_supply_elec__electricity__2005_01_01_00_00) | ||
-1 variables(flow_out)(b__test_supply_elec__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(b__test_demand_elec__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(b__test_demand_elec__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(b__test_transmission_elec_a__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(b__test_transmission_elec_a__electricity__2005_01_01_01_00) | ||
<= 0.0 | ||
|
||
c_u_constraints(net_annual_import_share_max)(c)_: | ||
+0.5 variables(flow_out)(c__test_transmission_elec_a__electricity__2005_01_01_00_00) | ||
+0.5 variables(flow_out)(c__test_transmission_elec_a__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(c__test_transmission_elec_a__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(c__test_transmission_elec_a__electricity__2005_01_01_01_00) | ||
<= 0.0 | ||
|
||
bounds | ||
1 <= ONE_VAR_CONSTANT <= 1 | ||
0 <= variables(flow_out)(a__test_transmission_elec_b__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(a__test_transmission_elec_b__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(a__test_transmission_elec_c__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(a__test_transmission_elec_c__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(a__test_supply_elec__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(a__test_supply_elec__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(a__test_demand_elec__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(a__test_demand_elec__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_elec_b__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_elec_b__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_elec_c__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_elec_c__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(b__test_transmission_elec_a__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(b__test_transmission_elec_a__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(b__test_supply_elec__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(b__test_supply_elec__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(b__test_demand_elec__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(b__test_demand_elec__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(b__test_transmission_elec_a__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(b__test_transmission_elec_a__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(c__test_transmission_elec_a__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(c__test_transmission_elec_a__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(c__test_transmission_elec_a__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(c__test_transmission_elec_a__electricity__2005_01_01_01_00) <= +inf | ||
end |
42 changes: 42 additions & 0 deletions
42
tests/common/lp_files/net_annual_import_share_max_node_group.lp
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,42 @@ | ||
\* Source Pyomo model name=None *\ | ||
|
||
min | ||
objectives(dummy_obj)(0): | ||
+2.0 ONE_VAR_CONSTANT | ||
|
||
s.t. | ||
|
||
c_u_constraints(net_annual_import_share_max_node_group)_: | ||
+0.5 variables(flow_out)(a__test_transmission_heat_b__heat__2005_01_01_00_00) | ||
+0.5 variables(flow_out)(a__test_transmission_heat_b__heat__2005_01_01_01_00) | ||
+0.5 variables(flow_out)(a__test_transmission_heat_c__heat__2005_01_01_00_00) | ||
+0.5 variables(flow_out)(a__test_transmission_heat_c__heat__2005_01_01_01_00) | ||
+0.5 variables(flow_out)(c__test_transmission_heat_a__heat__2005_01_01_00_00) | ||
+0.5 variables(flow_out)(c__test_transmission_heat_a__heat__2005_01_01_01_00) | ||
+1 variables(flow_in)(a__test_transmission_heat_b__heat__2005_01_01_00_00) | ||
+1 variables(flow_in)(a__test_transmission_heat_b__heat__2005_01_01_01_00) | ||
+1 variables(flow_in)(a__test_transmission_heat_c__heat__2005_01_01_00_00) | ||
+1 variables(flow_in)(a__test_transmission_heat_c__heat__2005_01_01_01_00) | ||
+1 variables(flow_in)(c__test_demand_heat__heat__2005_01_01_00_00) | ||
+1 variables(flow_in)(c__test_demand_heat__heat__2005_01_01_01_00) | ||
+1 variables(flow_in)(c__test_transmission_heat_a__heat__2005_01_01_00_00) | ||
+1 variables(flow_in)(c__test_transmission_heat_a__heat__2005_01_01_01_00) | ||
<= 0.0 | ||
|
||
bounds | ||
1 <= ONE_VAR_CONSTANT <= 1 | ||
0 <= variables(flow_out)(a__test_transmission_heat_b__heat__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(a__test_transmission_heat_b__heat__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(a__test_transmission_heat_c__heat__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(a__test_transmission_heat_c__heat__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(c__test_transmission_heat_a__heat__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(c__test_transmission_heat_a__heat__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_heat_b__heat__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_heat_b__heat__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_heat_c__heat__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_heat_c__heat__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(c__test_demand_heat__heat__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(c__test_demand_heat__heat__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(c__test_transmission_heat_a__heat__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(c__test_transmission_heat_a__heat__2005_01_01_01_00) <= +inf | ||
end |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,77 @@ | ||
\* Source Pyomo model name=None *\ | ||
|
||
min | ||
objectives(dummy_obj)(0): | ||
+2.0 ONE_VAR_CONSTANT | ||
|
||
s.t. | ||
|
||
c_u_constraints(net_import_share_max)(a__2005_01_01_00_00)_: | ||
+0.5 variables(flow_out)(a__test_transmission_elec_b__electricity__2005_01_01_00_00) | ||
+0.5 variables(flow_out)(a__test_transmission_elec_c__electricity__2005_01_01_00_00) | ||
-1 variables(flow_out)(a__test_supply_elec__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(a__test_demand_elec__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(a__test_transmission_elec_b__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(a__test_transmission_elec_c__electricity__2005_01_01_00_00) | ||
<= 0.0 | ||
|
||
c_u_constraints(net_import_share_max)(a__2005_01_01_01_00)_: | ||
+0.5 variables(flow_out)(a__test_transmission_elec_b__electricity__2005_01_01_01_00) | ||
+0.5 variables(flow_out)(a__test_transmission_elec_c__electricity__2005_01_01_01_00) | ||
-1 variables(flow_out)(a__test_supply_elec__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(a__test_demand_elec__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(a__test_transmission_elec_b__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(a__test_transmission_elec_c__electricity__2005_01_01_01_00) | ||
<= 0.0 | ||
|
||
c_u_constraints(net_import_share_max)(b__2005_01_01_00_00)_: | ||
+0.5 variables(flow_out)(b__test_transmission_elec_a__electricity__2005_01_01_00_00) | ||
-1 variables(flow_out)(b__test_supply_elec__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(b__test_demand_elec__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(b__test_transmission_elec_a__electricity__2005_01_01_00_00) | ||
<= 0.0 | ||
|
||
c_u_constraints(net_import_share_max)(b__2005_01_01_01_00)_: | ||
+0.5 variables(flow_out)(b__test_transmission_elec_a__electricity__2005_01_01_01_00) | ||
-1 variables(flow_out)(b__test_supply_elec__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(b__test_demand_elec__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(b__test_transmission_elec_a__electricity__2005_01_01_01_00) | ||
<= 0.0 | ||
|
||
c_u_constraints(net_import_share_max)(c__2005_01_01_00_00)_: | ||
+0.5 variables(flow_out)(c__test_transmission_elec_a__electricity__2005_01_01_00_00) | ||
+1 variables(flow_in)(c__test_transmission_elec_a__electricity__2005_01_01_00_00) | ||
<= 0.0 | ||
|
||
c_u_constraints(net_import_share_max)(c__2005_01_01_01_00)_: | ||
+0.5 variables(flow_out)(c__test_transmission_elec_a__electricity__2005_01_01_01_00) | ||
+1 variables(flow_in)(c__test_transmission_elec_a__electricity__2005_01_01_01_00) | ||
<= 0.0 | ||
|
||
bounds | ||
1 <= ONE_VAR_CONSTANT <= 1 | ||
0 <= variables(flow_out)(a__test_transmission_elec_b__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(a__test_transmission_elec_c__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(a__test_supply_elec__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(a__test_demand_elec__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_elec_b__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_elec_c__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(a__test_transmission_elec_b__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(a__test_transmission_elec_c__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(a__test_supply_elec__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(a__test_demand_elec__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_elec_b__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(a__test_transmission_elec_c__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(b__test_transmission_elec_a__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(b__test_supply_elec__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(b__test_demand_elec__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(b__test_transmission_elec_a__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(b__test_transmission_elec_a__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(b__test_supply_elec__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(b__test_demand_elec__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(b__test_transmission_elec_a__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_out)(c__test_transmission_elec_a__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_in)(c__test_transmission_elec_a__electricity__2005_01_01_00_00) <= +inf | ||
0 <= variables(flow_out)(c__test_transmission_elec_a__electricity__2005_01_01_01_00) <= +inf | ||
0 <= variables(flow_in)(c__test_transmission_elec_a__electricity__2005_01_01_01_00) <= +inf | ||
end |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters