Performance standards in t/MW (#1146)
- Loading branch information
Showing
104 changed files
with
1,210 additions
and
419 deletions.
There are no files selected for viewing
6 changes: 3 additions & 3 deletions
6
...tandard/geography_performance_standard_zones/1_geography_performance_standard_zones_1.csv
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,3 +1,3 @@ | ||
performance_standard_zone,allow_violation,violation_penalty_per_emission | ||
PS_Zone1,0,0 | ||
PS_Zone2,0,0 | ||
performance_standard_zone,energy_allow_violation,energy_violation_penalty_per_emission,power_allow_violation,power_violation_penalty_per_emission | ||
PS_Zone1,0,0,0,0 | ||
PS_Zone2,0,0,0,0 |
6 changes: 3 additions & 3 deletions
6
...licy/performance_standard/system_performance_standard/1_system_performance_standard_1.csv
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,3 +1,3 @@ | ||
performance_standard_zone,period,subproblem_id,stage_id,performance_standard_tco2_per_mwh | ||
PS_Zone1,2020,1,1,0.1 | ||
PS_Zone2,2020,1,1,0.1 | ||
performance_standard_zone,period,subproblem_id,stage_id,performance_standard_tco2_per_mwh,performance_standard_tco2_per_mw | ||
PS_Zone1,2020,1,1,0.1, | ||
PS_Zone2,2020,1,1,0.1, |
3 changes: 3 additions & 0 deletions
3
.../performance_standard/system_performance_standard/2_system_performance_standard_power.csv
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
performance_standard_zone,period,subproblem_id,stage_id,performance_standard_tco2_per_mwh,performance_standard_tco2_per_mw | ||
PS_Zone1,2020,1,1,,876 | ||
PS_Zone2,2020,1,1,,876 |
3 changes: 3 additions & 0 deletions
3
...y/performance_standard/system_performance_standard/3_system_performance_standard_both.csv
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
performance_standard_zone,period,subproblem_id,stage_id,performance_standard_tco2_per_mwh,performance_standard_tco2_per_mw | ||
PS_Zone1,2020,1,1,0.1,876 | ||
PS_Zone2,2020,1,1,0.1,876 |
Large diffs are not rendered by default.
Oops, something went wrong.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
6 changes: 3 additions & 3 deletions
6
examples/test_performance_standard/inputs/performance_standard.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,3 +1,3 @@ | ||
performance_standard_zone period performance_standard_tco2_per_mwh | ||
PS_Zone1 2020 0.1 | ||
PS_Zone2 2020 0.1 | ||
performance_standard_zone period performance_standard_tco2_per_mwh performance_standard_tco2_per_mw | ||
PS_Zone1 2020 0.1 . | ||
PS_Zone2 2020 0.1 . |
6 changes: 3 additions & 3 deletions
6
examples/test_performance_standard/inputs/performance_standard_zones.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,3 +1,3 @@ | ||
performance_standard_zone allow_violation violation_penalty_per_emission | ||
PS_Zone1 0 0.0 | ||
PS_Zone2 0 0.0 | ||
performance_standard_zone energy_allow_violation energy_violation_penalty_per_emission power_allow_violation power_violation_penalty_per_emission | ||
PS_Zone1 0 0.0 0 0.0 | ||
PS_Zone2 0 0.0 0 0.0 |
3 changes: 3 additions & 0 deletions
3
examples/test_performance_standard/inputs/project_performance_standard_zones.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
project performance_standard_zone | ||
Gas_CCGT PS_Zone1 | ||
Gas_CT PS_Zone2 |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,8 +1,8 @@ | ||
project capacity_type availability_type operational_type balancing_type_project technology load_zone variable_om_cost_per_mwh min_stable_level_fraction unit_size_mw startup_cost_per_mw shutdown_cost_per_mw startup_fuel_mmbtu_per_mw startup_plus_ramp_up_rate shutdown_plus_ramp_down_rate ramp_up_when_on_rate ramp_down_when_on_rate ramp_up_violation_penalty ramp_down_violation_penalty min_up_time_hours min_up_time_violation_penalty min_down_time_hours min_down_time_violation_penalty allow_startup_shutdown_power storage_efficiency charging_efficiency discharging_efficiency charging_capacity_multiplier discharging_capacity_multiplier minimum_duration_hours maximum_duration_hours aux_consumption_frac_capacity aux_consumption_frac_power last_commitment_stage curtailment_cost_per_pwh powerunithour_per_fuelunit soc_penalty_cost_per_energyunit soc_last_tmp_penalty_cost_per_energyunit partial_availability_threshold nonfuel_carbon_emissions_per_mwh lf_reserves_up_ba lf_reserves_up_derate lf_reserves_down_ba lf_reserves_down_derate regulation_up_ba regulation_up_derate regulation_down_ba regulation_down_derate lf_reserves_up_ramp_rate lf_reserves_down_ramp_rate regulation_up_ramp_rate regulation_down_ramp_rate performance_standard_zone | ||
Coal gen_spec exogenous gen_commit_cap day Coal Zone1 1.0 0.4 6.0 1.0 0.0 . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . . . . . Zone1 . Zone1 . . . . . . | ||
Gas_CCGT gen_spec exogenous gen_commit_cap day Gas Zone1 2.0 0.4 6.0 1.0 2.0 . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . Zone1 . Zone1 . Zone1 . Zone1 . . . . . PS_Zone1 | ||
Gas_CCGT_z2 gen_spec exogenous gen_commit_cap day Gas Zone2 2.0 0.4 6.0 1.0 2.0 . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . | ||
Gas_CT gen_spec exogenous gen_commit_cap day Gas Zone1 2.0 0.4 6.0 0.0 1.0 . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . . . . PS_Zone2 | ||
Nuclear gen_spec exogenous gen_must_run day Nuclear Zone1 1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | ||
Solar gen_new_lin exogenous gen_var day Solar Zone1 0.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | ||
Wind gen_spec exogenous gen_var day Wind Zone1 0.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | ||
project capacity_type availability_type operational_type balancing_type_project technology load_zone variable_om_cost_per_mwh min_stable_level_fraction unit_size_mw startup_cost_per_mw shutdown_cost_per_mw startup_fuel_mmbtu_per_mw startup_plus_ramp_up_rate shutdown_plus_ramp_down_rate ramp_up_when_on_rate ramp_down_when_on_rate ramp_up_violation_penalty ramp_down_violation_penalty min_up_time_hours min_up_time_violation_penalty min_down_time_hours min_down_time_violation_penalty allow_startup_shutdown_power storage_efficiency charging_efficiency discharging_efficiency charging_capacity_multiplier discharging_capacity_multiplier minimum_duration_hours maximum_duration_hours aux_consumption_frac_capacity aux_consumption_frac_power last_commitment_stage curtailment_cost_per_pwh powerunithour_per_fuelunit soc_penalty_cost_per_energyunit soc_last_tmp_penalty_cost_per_energyunit partial_availability_threshold nonfuel_carbon_emissions_per_mwh lf_reserves_up_ba lf_reserves_up_derate lf_reserves_down_ba lf_reserves_down_derate regulation_up_ba regulation_up_derate regulation_down_ba regulation_down_derate lf_reserves_up_ramp_rate lf_reserves_down_ramp_rate regulation_up_ramp_rate regulation_down_ramp_rate | ||
Coal gen_spec exogenous gen_commit_cap day Coal Zone1 1.0 0.4 6.0 1.0 0.0 . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . . . . . Zone1 . Zone1 . . . . . | ||
Gas_CCGT gen_spec exogenous gen_commit_cap day Gas Zone1 2.0 0.4 6.0 1.0 2.0 . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . Zone1 . Zone1 . Zone1 . Zone1 . . . . . | ||
Gas_CCGT_z2 gen_spec exogenous gen_commit_cap day Gas Zone2 2.0 0.4 6.0 1.0 2.0 . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . | ||
Gas_CT gen_spec exogenous gen_commit_cap day Gas Zone1 2.0 0.4 6.0 0.0 1.0 . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . . . . | ||
Nuclear gen_spec exogenous gen_must_run day Nuclear Zone1 1.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | ||
Solar gen_new_lin exogenous gen_var day Solar Zone1 0.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | ||
Wind gen_spec exogenous gen_var day Wind Zone1 0.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,7 @@ | ||
features | ||
transmission | ||
lf_reserves_up | ||
lf_reserves_down | ||
regulation_up | ||
regulation_down | ||
performance_standard |
9 changes: 9 additions & 0 deletions
9
examples/test_performance_standard_both/inputs/fuel_prices.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,9 @@ | ||
fuel period month fuel_price_per_mmbtu | ||
Coal 2020 1 4.0 | ||
Coal 2020 2 4.0 | ||
Gas 2020 1 5.0 | ||
Gas 2020 2 5.0 | ||
Negative_Carbon_Fuel 2020 1 6.0 | ||
Negative_Carbon_Fuel 2020 2 6.0 | ||
Uranium 2020 1 2.0 | ||
Uranium 2020 2 2.0 |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,5 @@ | ||
fuel co2_intensity_tons_per_mmbtu fuel_group | ||
Coal 0.09552 Solid | ||
Gas 0.05306 Gas | ||
Negative_Carbon_Fuel -0.1 Gas | ||
Uranium 0.0 Other |
10 changes: 10 additions & 0 deletions
10
examples/test_performance_standard_both/inputs/heat_rate_curves.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,10 @@ | ||
project period load_point_fraction average_heat_rate_mmbtu_per_mwh | ||
Coal 0 0.4 1250.0 | ||
Coal 0 1.0 506.0 | ||
Gas_CCGT 0 0.5 506.0 | ||
Gas_CCGT 0 1.0 256.0 | ||
Gas_CCGT_z2 0 0.5 506.0 | ||
Gas_CCGT_z2 0 1.0 256.0 | ||
Gas_CT 0 0.4 208.33333 | ||
Gas_CT 0 1.0 88.13333 | ||
Nuclear 0 1.0 1666.67 |
3 changes: 3 additions & 0 deletions
3
examples/test_performance_standard_both/inputs/horizon_timepoints.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
horizon balancing_type_horizon timepoint | ||
202001 day 20200101 | ||
202001 day 20200102 |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,2 @@ | ||
horizon balancing_type_horizon boundary | ||
202001 day circular |
3 changes: 3 additions & 0 deletions
3
examples/test_performance_standard_both/inputs/lf_reserves_down_tmp_requirement.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
ba timepoint requirement | ||
Zone1 20200101 1.0 | ||
Zone1 20200102 2.0 |
3 changes: 3 additions & 0 deletions
3
examples/test_performance_standard_both/inputs/lf_reserves_up_tmp_requirement.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
ba timepoint requirement | ||
Zone1 20200101 1.0 | ||
Zone1 20200102 2.0 |
2 changes: 2 additions & 0 deletions
2
examples/test_performance_standard_both/inputs/load_following_down_balancing_areas.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,2 @@ | ||
balancing_area allow_violation violation_penalty_per_mw reserve_to_energy_adjustment | ||
Zone1 1 999999999.0 . |
2 changes: 2 additions & 0 deletions
2
examples/test_performance_standard_both/inputs/load_following_up_balancing_areas.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,2 @@ | ||
balancing_area allow_violation violation_penalty_per_mw reserve_to_energy_adjustment | ||
Zone1 1 999999999.0 . |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,5 @@ | ||
LOAD_ZONES timepoint load_mw | ||
Zone1 20200101 10.0 | ||
Zone1 20200102 20.0 | ||
Zone2 20200101 10.0 | ||
Zone2 20200102 10.0 |
3 changes: 3 additions & 0 deletions
3
examples/test_performance_standard_both/inputs/load_zones.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
load_zone allow_overgeneration overgeneration_penalty_per_mw allow_unserved_energy unserved_energy_penalty_per_mwh unserved_energy_limit_mwh max_unserved_load_penalty_per_mw max_unserved_load_limit_mw export_penalty_cost_per_mwh | ||
Zone1 1 99999999.0 1 99999999.0 . 0.0 . 0.0 | ||
Zone2 1 99999999.0 1 99999999.0 . 0.0 . 0.0 |
2 changes: 2 additions & 0 deletions
2
examples/test_performance_standard_both/inputs/new_build_generator_vintage_costs.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,2 @@ | ||
project vintage operational_lifetime_yrs fixed_cost_per_mw_yr financial_lifetime_yrs annualized_real_cost_per_mw_yr | ||
Solar 2020 30.0 0.0 30.0 100.0 |
2 changes: 2 additions & 0 deletions
2
examples/test_performance_standard_both/inputs/new_build_potentials.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,2 @@ | ||
project period min_new_build_power max_new_build_power min_capacity_power max_capacity_power min_new_build_energy max_new_build_energy min_capacity_energy max_capacity_energy | ||
Solar 2020 . . 0.0 2.0 . . . . |
3 changes: 3 additions & 0 deletions
3
examples/test_performance_standard_both/inputs/performance_standard.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
performance_standard_zone period performance_standard_tco2_per_mwh performance_standard_tco2_per_mw | ||
PS_Zone1 2020 0.1 876.0 | ||
PS_Zone2 2020 0.1 876.0 |
3 changes: 3 additions & 0 deletions
3
examples/test_performance_standard_both/inputs/performance_standard_zones.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
performance_standard_zone energy_allow_violation energy_violation_penalty_per_emission power_allow_violation power_violation_penalty_per_emission | ||
PS_Zone1 0 0.0 0 0.0 | ||
PS_Zone2 0 0.0 0 0.0 |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,2 @@ | ||
period discount_factor period_start_year period_end_year hours_in_period_timepoints | ||
2020 1.0 2020.0 2021.0 8760.0 |
7 changes: 7 additions & 0 deletions
7
examples/test_performance_standard_both/inputs/project_fuels.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,7 @@ | ||
project fuel min_fraction_in_fuel_blend max_fraction_in_fuel_blend | ||
Coal Coal . . | ||
Gas_CCGT Gas 0.0 1.0 | ||
Gas_CCGT Negative_Carbon_Fuel 0.0 1.0 | ||
Gas_CCGT_z2 Gas . . | ||
Gas_CT Gas . . | ||
Nuclear Uranium . . |
3 changes: 3 additions & 0 deletions
3
examples/test_performance_standard_both/inputs/project_performance_standard_zones.tab
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
project performance_standard_zone | ||
Gas_CCGT PS_Zone1 | ||
Gas_CT PS_Zone2 |