An issue was discovered in URVE Build 24.03.2020. Using...
Critical severity
Unreviewed
Published
May 24, 2022
to the GitHub Advisory Database
•
Updated Jan 29, 2023
Description
Published by the National Vulnerability Database
Dec 23, 2020
Published to the GitHub Advisory Database
May 24, 2022
Last updated
Jan 29, 2023
An issue was discovered in URVE Build 24.03.2020. Using the _internal/pc/shutdown.php path, it is possible to shutdown the system. Among others, the following files and scripts are also accessible: _internal/pc/abort.php, _internal/pc/restart.php, _internal/pc/vpro.php, _internal/pc/wake.php, _internal/error_u201409.txt, _internal/runcmd.php, _internal/getConfiguration.php, ews/autoload.php, ews/del.php, ews/mod.php, ews/sync.php, utils/backup/backup_server.php, utils/backup/restore_server.php, MyScreens/timeline.config, kreator.html5/test.php, and addedlogs.txt.