23 changes: 19 additions & 4 deletions api/docs/v2/moving_labware.rst
Original file line number Diff line number Diff line change
Expand Up @@ -24,16 +24,30 @@ Use the :py:meth:`.ProtocolContext.move_labware` method to initiate a move, rega

The required arguments of ``move_labware()`` are the ``labware`` you want to move and its ``new_location``. You don't need to specify where the move begins, since that information is already stored in the :py:class:`Labware` object with the name ``plate``. That information gets updated when the move step is complete, so you can move a plate multiple times::

protocol.move_labware(labware=plate, new_location='D2')
protocol.move_labware(labware=plate, new_location='D3')
protocol.move_labware(labware=plate, new_location='D2')
protocol.move_labware(labware=plate, new_location='D3')
For the first move, the API knows to find the plate in its initial load location, slot D1. For the second move, the API knows to find the plate in D2.


Automated vs Manual Moves
=========================

Opentrons Flex supports an additional ``use_gripper`` parameter of :py:meth:`~.ProtocolContext.move_labware` for moving labware with the gripper. Set its value to ``True`` to have the gripper pick up and move the labware without user intervention or pausing the protocol. The default value is ``False``, so if you don't specify a value, the protocol will pause for you to manually move the labware.

.. code-block:: python
plate = protocol.load_labware('nest_96_wellplate_200ul_flat', 'D1')
# have the gripper move the plate from D1 to D2
protocol.move_labware(labware=plate, new_location='D2', use_gripper=True)
# pause to move the plate manually from D2 to D3
protocol.move_labware(labware=plate, new_location='D3', use_gripper=False)
# pause to move the plate manually from D3 to C1
protocol.move_labware(labware=plate, new_location='C1')
.. versionadded:: 2.15