Skip to content

Releases: KLDistance/NanoCVD

NanoCVD v0.8.6

23 Feb 20:16
Compare
Choose a tag to compare

NanoCVD v0.8.6

New Features:

  1. Append 3-way FMA6702 flowmeters into the system, with RS232 to RS485 conversion adapter inside the box.
  2. Flowrate monitor window tab for propane, butane and argon gas, with designed refresh rate at 660ms.

NanoCVD v0.8.5

07 Aug 23:15
Compare
Choose a tag to compare

NanoCVD v0.8.5

Bug Fixed:

  1. Extended LUT power supply voltage output to arduino input mapping.
  2. Synchronize the "Wait" and "Vel" parameters, make motion time independent on the quiescent time.
  3. Solve the occasional abnormal response on setting velocity of the CNCRouter.

NanoCVD v0.8

17 Jul 19:45
Compare
Choose a tag to compare

NanoCVD v0.8

New Features:

  1. Support pseudo USB plug-and-play function through refresh button.
  2. Modified Save and Load of file path operation through QSettings memory.

NanoCVD v0.7

09 Jul 14:16
Compare
Choose a tag to compare

NanoCVD v0.7

Bug Fixed:

  1. Abnormal QMessageBox breaks down when serial port connection is invalid. Move the response to GUI thread.
  2. Shrink the timeout for device detection from 5s to 3s.

NanoCVD v0.6

07 Jul 14:32
Compare
Choose a tag to compare

NanoCVD v0.6

Bug Fixed:

  1. Change window title and icons.
  2. Validate serial port transmission problem.
  3. Power supply voltage LUT load check.

New Features:

  1. Add prograss bar monitoring.
  2. Modified keyboard response while "keyboard input" checkbox is enabled.

NanoCVD v0.5

03 Jul 22:22
Compare
Choose a tag to compare

NanoCVD v0.5


A win7, 8, 8.1, and 10 release.
64-bit operating system required.
Processor minimum: 6th gen i3/5/7 or 1th gen AMD Ryzen or better to ensure a success run.