You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The sick_tim ROS driver seems to work well when the SICK MRS1000 is sending only first or last echo: both range and intensity measurements are published correctly. If the MRS1000 is configured to send all the three echoes (with or without intensities) the sick_tim prints repeatedly following warnings:
[ WARN] [1533648107.591137655]: Number of RSSI data is lower than number of range data (1101 vs 5061
[ WARN] [1533648107.611167093]: Number of RSSI data is lower than number of range data (1101 vs 4944
and no data is published.
So it seems currently there is no multiple echoes (three in case of SICK MRS1000) support in the sick_tim ROS driver, but it would be great if it could be added!
The text was updated successfully, but these errors were encountered:
The sick_tim ROS driver seems to work well when the SICK MRS1000 is sending only first or last echo: both range and intensity measurements are published correctly. If the MRS1000 is configured to send all the three echoes (with or without intensities) the sick_tim prints repeatedly following warnings:
[ WARN] [1533648107.591137655]: Number of RSSI data is lower than number of range data (1101 vs 5061
[ WARN] [1533648107.611167093]: Number of RSSI data is lower than number of range data (1101 vs 4944
and no data is published.
So it seems currently there is no multiple echoes (three in case of SICK MRS1000) support in the sick_tim ROS driver, but it would be great if it could be added!
The text was updated successfully, but these errors were encountered: