According to RFC 7587:

The "useinbandfec" parameter is a unidirectional receive-only
      parameter.
useinbandfec:  specifies that the decoder has the capability to take
      advantage of the Opus in-band FEC.

So if remote FMTP signals that it doesn't wish to use FEC, it should have no impact to our local/decoding PLC setting, attr->setting.plc, which will be used by stream to decide whether to recover a frame.

@sauwming sauwming merged commit 9b10599 into master Jul 12, 2024