function run_src_dcx_1_single()
% Compute a SRC-DCX transformer design and display the results
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% (c) 2021, T. Guillod, BSD License
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
close('all');
addpath(genpath('example_files'))
addpath('magnetic_toolbox')
add_path_mag_tb(false)
%% data
flag = get_spec_flag(); % converter specifications
param.f_sw = 100e3; % switching frequency
param.r_gap = 0.005; % relative air gap length
param.A_core = 750e-6; % core cross section
param.r_core = 3.0; % core aspect ratio
param.A_litz_lv = 14.0e-6; % wire copper area (LV side)
param.A_litz_hv = 3.0e-6; % wire copper area (HV side)
param.n_winding_lv = 3; % number of turns (LV side)
param.n_winding_hv = 12; % number of turns (HV side)
%% fct for analyzing a transformer design
fct_solve = @(param) get_transformer_fct_solve(param, true);
%% run
data = get_sweep_single('SRC-DCX / single', flag, param, fct_solve);
end