-
Notifications
You must be signed in to change notification settings - Fork 60
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Importing CLD models from FCCDetectors, new CLD Model with overlaps fixed #280
Conversation
FCCee/CLD/compact/CLD_o2_v05/BeamInstrumentation_o3_v02_fitShield.xml
Outdated
Show resolved
Hide resolved
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Some more suggestions but otherwise LGTM
<constant name="DetID_LumiCalCooling" value=" 17"/> | ||
<constant name="DetID_LumiCalNoseShield" value=" 22"/> | ||
|
||
<constant name="DetID_HOMAbsorber" value=" 19"/> |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Do we still need an ID for the HOMAbsorber if we no longer have a HOMAbsorber?
Hi @andresailer I also agree with @armin-ilg that the central chamber should be described as 3 layers, but if it is technically challenging I think also the mixed material could work. I am also working on the CAD model import for the beam pipe, I will try to make a PR this week, so that we have also the copper cooling sections and a more realistic profile for the conical/trapezoidal section (which now is circular, but in reality should be elliptical). |
The vertex and beampipe radii are larger than they should be for an option 2 model
…umical and beampipe design with parafin cooling
The geant version in LCG_103 prints some verbose warnings about the fourth TA Shield, this seems to be spurious and due to a faulty check of rmin vs rmax? This only happens when the detector is drawn. Overlap check is clean
Fix overlap of modules going outside the envelope by reducing the inner clearance to 149 mrad half opening angle
The number of modules around phi has to be the same for all radii, use the correct module to cover the complete phi angle
…ing to too large radius
BEGINRELEASENOTES
FCCee_o2_v03: Copy of FCCDetectors FCC_o2_v03, and renaming of XML files to make diff with existing models easier, this model is obsolete
FCCee_o2_v04: Copy of FCCDetectors FCC_o2_v04, and renaming of XML files to make diff easier
CLD_o2_v05: New implementation of the CLD detector with small beampipe design according to latest standard design; modified vertex detector to fit into the beampipe constraints (reduced length of all barrel layers, based on FCCee_o2_v02 from k4Geo); fixed overlaps in Inner and Outer Tracker
ENDRELEASENOTES
Todo: