P. 8, bottom, reads:

"A convenient trick to remember this conversion is that 14.0 fL almost exactly to 48.0 cd/m2 ,
which coincidentally also happens to be the recommended target luminance for projected theatrical
white."

I think this should read: A convenient trick to remember this conversion is that 14.0 fL is almost exactly equal to 48.0 cd/m2 ,which coincidentally also happens to be the recommended target luminance for projected theatrical white.