[Master] unable to enter cli tab with SITL #2053

Closed
RomanLut opened this issue Apr 29, 2024 · 3 comments
Closed

[Master] unable to enter cli tab with SITL #2053

RomanLut opened this issue Apr 29, 2024 · 3 comments

Comments

@RomanLut
Copy link
Contributor

Unable to enter cli with SITL.

Reproduction:

  1. Start SITL
  2. Connect to SITL
  3. Switch to CLI tab
    => Interface resets to home screen.

Tested with current Master branch, sitl executable from configurator master and sitl executable built from inav master, windows.

@stronnag
Copy link
Collaborator

Same happens on Linux. This is not a SITL issue, as that works OK with the CLI outside of configurator.

@breadoven
Copy link
Collaborator

breadoven commented Apr 29, 2024

It's to do with #2048, same for the Firmware update.

@DzikuVx
Copy link
Member

DzikuVx commented Apr 30, 2024

Fixed in #2054

@DzikuVx DzikuVx closed this as completed Apr 30, 2024