Skip to content

Latest commit

 

History

History
1084 lines (494 loc) · 16.3 KB

class1.measurezone.md

File metadata and controls

1084 lines (494 loc) · 16.3 KB

Class=65 (0x41) - Measurement with zone

CLASS1.MEASUREZONE

Description

Measurements with zone information. This class mirrors the standard measurement events is CLASS1.MEASUREMENT=10 with the difference that index, zone, and sub-zone is added. This in turn limits the data-coding options to normalized integer (see Data-coding for a description). The default unit for the measurement should always be used.

Byte Description
0 Index for device (This is NOT the same as senorindex is in data coding byte).
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.
3 Data coding.
4-7 Data with format defined by byte 0.

Type=0 (0x00) - General event :id=type0

VSCP_TYPE_MEASUREMENT_GENERAL

This is a general (custom) measurement event that can be used if no other event is suitable.


Type=1 (0x01) - Count :id=type1

VSCP_TYPE_MEASUREMENT_COUNT

This is a discrete value typical for a count. There is no unit for this measurement just a discrete value.


Type=2 (0x02) - Length/Distance :id=type2

VSCP_TYPE_MEASUREMENT_LENGTH

Default unit: Meter.

This is a measurement of a length or a distance.


Type=3 (0x03) - Mass :id=type3

VSCP_TYPE_MEASUREMENT_MASS

Default unit: Kilogram.

This is a measurement of a mass.


Type=4 (0x04) - Time :id=type4

VSCP_TYPE_MEASUREMENT_TIME

A time measurement.

Default unit: Seconds.
Opt. unit: (1) Milliseconds. Absolute: (2) y-y-m-d-h-m-s (binary). String: (3) "HHMMSS".


Type=5 (0x05) - Electric Current :id=type5

VSCP_TYPE_MEASUREMENT_ELECTRIC_CURRENT

Default unit: Ampere.

This is a measurement of an electric current.


Type=6 (0x06) - Temperature :id=type6

VSCP_TYPE_MEASUREMENT_TEMPERATURE

Default unit: Kelvin.
Opt. unit: Degree Celsius (1), Fahrenheit (2)

This is a measurement of a temperature.


Type=7 (0x07) - Amount of substance :id=type7

VSCP_TYPE_MEASUREMENT_AMOUNT_OF_SUBSTANCE

Default unit: Mole.

This is a measurement of an amount of a substance.


Type=8 (0x08) - Luminous Intensity (Intensity of light) :id=type8

VSCP_TYPE_MEASUREMENT_INTENSITY_OF_LIGHT

Default unit: Candela.

This is a measurement of luminous intensity.


Type=9 (0x09) - Frequency :id=type9

VSCP_TYPE_MEASUREMENT_FREQUENCY

Default unit: Hertz.

This is a measurement of regular events during a second.


Type=10 (0x0A) - Radioactivity and other random events :id=type10

VSCP_TYPE_MEASUREMENT_RADIOACTIVITY

Default unit: becquerel. Optional unit: curie (1)

This is a measurement of rates of things, which happen randomly, or are unpredictable.


Type=11 (0x0B) - Force :id=type11

VSCP_TYPE_MEASUREMENT_FORCE

Default unit: newton.

This is a measurement of force.


Type=12 (0x0C) - Pressure :id=type12

VSCP_TYPE_MEASUREMENT_PRESSURE

Default unit: pascal.
Opt. unit: bar (1), psi (2)

This is a measurement of pressure.


Type=13 (0x0D) - Energy :id=type13

VSCP_TYPE_MEASUREMENT_ENERGY

Default unit: Joule.
Optional unit: KWh (1)

This is a measurement of energy.


Type=14 (0x0E) - Power :id=type14

VSCP_TYPE_MEASUREMENT_POWER

Default unit: watt.
Optional unit: Horse power (1).

This is a measurement of power.


Type=15 (0x0F) - Electrical Charge :id=type15

VSCP_TYPE_MEASUREMENT_ELECTRICAL_CHARGE

Default unit: coulomb.

This is a measurement electrical charge.


Type=16 (0x10) - Electrical Potential (Voltage) :id=type16

VSCP_TYPE_MEASUREMENT_ELECTRICAL_POTENTIAL

Default unit: volt.

This is a measurement of electrical potential.


Type=17 (0x11) - Electrical Capacitance :id=type17

VSCP_TYPE_MEASUREMENT_ELECTRICAL_CAPACITANCE

Default unit: farad (F).

This is a measurement of electric capacitance.


Type=18 (0x12) - Electrical Resistance :id=type18

VSCP_TYPE_MEASUREMENT_ELECTRICAL_RESISTANCE

Default unit: ohm (Ω).

This is a measurement of resistance.


Type=19 (0x13) - Electrical Conductance :id=type19

VSCP_TYPE_MEASUREMENT_ELECTRICAL_CONDUCTANCE

Default unit: siemens.

This is a measurement of electrical conductance.


Type=20 (0x14) - Magnetic Field Strength :id=type20

VSCP_TYPE_MEASUREMENT_MAGNETIC_FIELD_STRENGTH

Default unit: amperes per meter (H).
Optional units: teslas (B) (1)

This is a measurement of magnetic field strength.


Type=21 (0x15) - Magnetic Flux :id=type21

VSCP_TYPE_MEASUREMENT_MAGNETIC_FLUX

Default unit: weber (Wb).

This is a measurement of magnetic flux.


Type=22 (0x16) - Magnetic Flux Density :id=type22

VSCP_TYPE_MEASUREMENT_MAGNETIC_FLUX_DENSITY

Default unit: tesla (B).

Optional unit: Gauss (1)

This is a measurement of flux density or field strength for magnetic fields (also called the magnetic induction).


Type=23 (0x17) - Inductance :id=type23

VSCP_TYPE_MEASUREMENT_INDUCTANCE

Default unit: henry (H).

This is a measurement of inductance.


Type=24 (0x18) - Luminous Flux :id=type24

VSCP_TYPE_MEASUREMENT_FLUX_OF_LIGHT

Default unit: Lumen (lm= cd * sr)

This is a measurement of luminous Flux.


Type=25 (0x19) - Illuminance :id=type25

VSCP_TYPE_MEASUREMENT_ILLUMINANCE

Default unit: lux (lx) ( lx = lm / m² )

This is used to express both Illuminance (incidence of light) and Luminous Emittance (emission of light).


Type=26 (0x1A) - Radiation dose (absorbed) :id=type26

VSCP_TYPE_MEASUREMENT_RADIATION_DOSE_ABSORBED

Default unit: gray (Gy).

This is a measurement of a radiation dose (Absorbed dose of ionizing radiation).


Type=27 (0x1B) - Catalytic activity :id=type27

VSCP_TYPE_MEASUREMENT_CATALYTIC_ACITIVITY

Default unit: katal (kat).

This is a measurement of catalytic activity used in biochemistry.


Type=28 (0x1C) - Volume :id=type28

VSCP_TYPE_MEASUREMENT_VOLUME

Default unit: cubic meter (m³)
Opt. unit: Liter (dm³) (1), decilitre (100 cm³) (2), centilitre (10 cm³) (3), millilitre (cm³) (4) where unit 4 is only available for Level II measurement events where units can hold this value.

This is a measurement of volume.


Type=29 (0x1D) - Sound intensity :id=type29

VSCP_TYPE_MEASUREMENT_SOUND_INTENSITY

Default unit: W/m2, watt per square meter.

This is a measurement of sound intensity (acoustic intensity).


Type=30 (0x1E) - Angle, direction or similar :id=type30

VSCP_TYPE_MEASUREMENT_ANGLE
  • Default unit: radian (rad) (Plane angles).
  • Opt Unit: degree (1).
  • Opt Unit: arcminute (2).
  • Opt Unit: arcseconds (3).

This is a measurement of an angle or a direction or similar.


Type=31 (0x1F) - Position WGS 84 :id=type31

VSCP_TYPE_MEASUREMENT_POSITION

Default unit: Longitude.
Opt. unit: Latitude.

This is a (decimal) measurement of a position as of WGS 84. Normally given as a floating point value. See ./class1.gps.md for a better candidate to use for position data.


Type=32 (0x20) - Speed :id=type32

VSCP_TYPE_MEASUREMENT_SPEED

Default unit: Meters per second.
Optional unit: Kilometers per hour (1) Miles per hour (2)

This is a measurement of a speed.


Type=33 (0x21) - Acceleration :id=type33

VSCP_TYPE_MEASUREMENT_ACCELERATION

Default unit: Meters per second/second (m/s2).

This is a measurement of acceleration.


Type=34 (0x22) - Tension :id=type34

VSCP_TYPE_MEASUREMENT_TENSION

Default unit: N/m.

This is a measurement of tension.


Type=35 (0x23) - Damp/moist (Hygrometer reading) :id=type35

VSCP_TYPE_MEASUREMENT_HUMIDITY

Default unit: Relative percentage 0-100%.

This is a measurement of relative moistness (Humidity).


Type=36 (0x24) - Flow :id=type36

VSCP_TYPE_MEASUREMENT_FLOW

Default unit: Cubic meters/second.
Opt Unit: Liters/Second.

This is a measurement of flow.


Type=37 (0x25) - Thermal resistance :id=type37

VSCP_TYPE_MEASUREMENT_THERMAL_RESISTANCE

Default unit: Thermal ohm K/W.

This is a measurement of thermal resistance.


Type=38 (0x26) - Refractive (optical) power :id=type38

VSCP_TYPE_MEASUREMENT_REFRACTIVE_POWER

Default unit: dioptre (dpt) m-1.

This is a measurement of refractive (optical) power.


Type=39 (0x27) - Dynamic viscosity :id=type39

VSCP_TYPE_MEASUREMENT_DYNAMIC_VISCOSITY

Default unit: pascal second optional units poiseuille (Pl) = 1, poise (P) = 2

This is a measurement of dynamic viscosity.


Type=40 (0x28) - Sound impedance :id=type40

VSCP_TYPE_MEASUREMENT_SOUND_IMPEDANCE

Default unit: rayl (Pa·s/m)

This is a measurement of sound impedance.


Type=41 (0x29) - Sound resistance :id=type41

VSCP_TYPE_MEASUREMENT_SOUND_RESISTANCE

Default unit: Acoustic ohm Pa · s/ m³.

This is a measurement of sound resistance.


Type=42 (0x2A) - Electric elastance :id=type42

VSCP_TYPE_MEASUREMENT_ELECTRIC_ELASTANCE

Default unit: daraf (f-1).

This is a measurement of electric elasticity.


Type=43 (0x2B) - Luminous energy :id=type43

VSCP_TYPE_MEASUREMENT_LUMINOUS_ENERGY

Default unit: talbot ( tb = lm * s)

This is a measurement of luminous energy.


Type=44 (0x2C) - Luminance :id=type44

VSCP_TYPE_MEASUREMENT_LUMINANCE

Default unit: cd / m²) (non SI unit = nit)

This is a measurement of luminance.


Type=45 (0x2D) - Chemical (molar) concentration :id=type45

VSCP_TYPE_MEASUREMENT_CHEMICAL_CONCENTRATION_MOLAR

Default unit: mol/m3.

This is a measurement of chemical mol concentration.


Type=46 (0x2E) - Chemical (mass) concentration :id=type46

VSCP_TYPE_MEASUREMENT_CHEMICAL_CONCENTRATION_MASS

Default unit: kg/m3.

This is a measurement of chemical mass concentration.


Type=47 (0x2F) - Reserved :id=type47

VSCP_TYPE_MEASUREMENT_DOSE_EQVIVALENT

Reserved


Type=48 (0x30) - Reserved :id=type48

VSCP_TYPE_MEASUREMENT_RESERVED48

Reserved


Type=49 (0x31) - Dew Point :id=type49

VSCP_TYPE_MEASUREMENT_DEWPOINT

Default unit: Kelvin.
Opt. unit: Degree Celsius (1), Fahrenheit (2)

This is a measurement of the Dew Point.


Type=50 (0x32) - Relative Level :id=type50

VSCP_TYPE_MEASUREMENT_RELATIVE_LEVEL

Default unit: Relative value.

This is a relative value for a level measurement without a unit. It is just relative to the min/max value for the selected data representation, typically percentage or per mille or similar.


Type=51 (0x33) - Altitude :id=type51

VSCP_TYPE_MEASUREMENT_ALTITUDE

Default unit: Meter.
Opt. unit: Feet(1), inches (2)

Altitude in meters.


Type=52 (0x34) - Area :id=type52

VSCP_TYPE_MEASUREMENT_AREA

Default unit: square meter (m²)

Area in square meter.


Type=53 (0x35) - Radiant intensity :id=type53

VSCP_TYPE_MEASUREMENT_RADIANT_INTENSITY

Default unit: watt per steradian ( W / sr )

Radiated power per room angle.


Type=54 (0x36) - Radiance :id=type54

VSCP_TYPE_MEASUREMENT_RADIANCE

Default unit: watt per steradian per square metre ( W / (sr * m²) )

This is the radiant flux emitted, reflected, transmitted or received by a surface.


Type=55 (0x37) - Irradiance, Exitance, Radiosity :id=type55

VSCP_TYPE_MEASUREMENT_IRRADIANCE

Default unit: watt per square metre ( W / m² )

Power emitted from or striking onto a surface or area.


Type=56 (0x38) - Spectral radiance :id=type56

VSCP_TYPE_MEASUREMENT_SPECTRAL_RADIANCE

Default unit: watt per steradian per square metre per nm (W·sr-1·m-2·nm-1)
Opt. unit: watt per steradian per meter3 (W·sr-1·m-3) (1), watt per steradian per square metre per hertz (W·sr-1·m-3) (2)

Radiance of a surface per unit frequency or wavelength.


Type=57 (0x39) - Spectral irradiance :id=type57

VSCP_TYPE_MEASUREMENT_SPECTRAL_IRRADIANCE

Default unit: watt per square metre per nm (W·m-2·nm-1)
Opt. unit: watt per metre3 (W·m-3) (1), watt per square metre per hertz (W·m-2·Hz-1) (2)

Irradiance of a surface per unit frequency or wavelength.


Type=58 (0x3A) - Sound pressure (acoustic pressure) :id=type58

VSCP_TYPE_MEASUREMENT_SOUND_PRESSURE

Default unit: pascal (Pa)

This is a measurement of sound pressure (acoustic pressure).


Type=59 (0x3B) - Sound energy density :id=type59

VSCP_TYPE_MEASUREMENT_SOUND_DENSITY

Default unit: pascal (Pa)

Sound energy density or sound density is the sound energy per unit volume.


Type=60 (0x3C) - Sound level :id=type60

VSCP_TYPE_MEASUREMENT_SOUND_LEVEL

Default unit: decibel (dB)

Sound level expressed in decibel. This event is supplied for convenience.


Type=61 (0x3D) - Radiation dose (equivalent) :id=type61

VSCP_TYPE_MEASUREMENT_RADIATION_DOSE_EQ

Default unit: sievert (Sv).

Optional unit rem (1)

This is a measurement of a radiation dose (Equivalent dose of ionizing radiation).


Type=62 (0x3E) - Radiation dose (exposure) :id=type62

VSCP_TYPE_MEASUREMENT_RADIATION_DOSE_EXPOSURE

Default unit: coulomb per kilogram (C/kg).
Optional unit: Röntgen/R (1)

This is a measurement of a radiation dose (Exposed dose of ionizing radiation).


Type=63 (0x3F) - Power factor :id=type63

VSCP_TYPE_MEASUREMENT_POWER_FACTOR

Default unit: cos of phase angle.

This is a measurement of a power factor. Power factor is an expression of energy efficiency. It is usually expressed as a percentage—and the lower the percentage, the less efficient power usage is.

Power factor (PF) is the ratio of working power, measured in kilowatts (kW), to apparent power, measured in kilovolt amperes (kVA). Apparent power, also known as demand, is the measure of the amount of power used to run machinery and equipment during a certain period. It is found by multiplying (kVA = V x A). The result is expressed as kVA units.


Type=64 (0x40) - Reactive Power :id=type64

VSCP_TYPE_MEASUREMENT_REACTIVE_POWER

Default unit: VAr

In electric power transmission and distribution, volt-ampere reactive (VAr) is a unit of measurement of reactive power. Reactive power exists in an AC circuit when the current and voltage are not in phase. The term var was proposed by the Romanian electrical engineer Constantin Budeanu and introduced in 1930 by the IEC in Stockholm, which has adopted it as the unit for reactive power. Special instruments called varmeters are available to measure the reactive power in a circuit. The unit "var" is allowed by the International System of Units (SI) even though the unit var is representative of a form of power. SI allows one to specify units to indicate common sense physical considerations. Per EU directive 80/181/EEC (the "metric directive"), the correct symbol is lower-case "var", although the spellings "Var" and "VAr" are commonly seen, and "VAR" is widely used throughout the power industry.

Definition from Wikipedia


Type=65 (0x41) - Reactive Energy :id=type65

VSCP_TYPE_MEASUREMENT_REACTIVE_ENERGY

Default unit: kVArh

Reactive Energy is the electrical Energy produced, flowing or supplied by an electric circuit during a time interval, measured in units of kVArh or standard multiples thereof.


filename