Serial 3: GND missing #11
Comments
Good catch @imuguruza. This is indeed the reason why in my tests the Serial 3 doesn't respond at all. @proficnc is there a reason why the |
Nice catch! Victor, can you confirm it works as planned with a ground from somewhere else? Philip Rowse
|
@proficnc i confirm that with a ground hacked to those pins it powers modules but the BBB still doesn't receive properly (no activity on |
@proficnc have we tried removing the CAN IC? |
No, we haven't, worth a try |
While I was reviewing the design, I have noticed that the
Serial 3
(sheet nº2) has notGND
signal connected. This could be the reason why the port can't power up connected modules.In this image, it can be appreciated:
The text was updated successfully, but these errors were encountered: