Skip to content

Latest commit

 

History

History
655 lines (506 loc) · 17.5 KB

mu.md

File metadata and controls

655 lines (506 loc) · 17.5 KB

Mu Reference

Mu programs are sequences of fn and type definitions.

Functions

Define functions with the fn keyword. For example:

  fn foo arg1: int, arg2: int -> _/eax: boolean

Functions contain {} blocks, var declarations, primitive statements and calls to other functions. Only {} blocks can nest. Primitive statements and function calls look similar:

  out1, out2, out3, ... <- operation inout1, inout2, inout3, ...

They can take any number of inouts and outputs, including 0. Statements with 0 outputs also drop the <-.

Inouts can be either variables in memory, variables in registers, or literal constants (either integers or string literals that get replaced with constant addresses). Outputs are always variables in registers.

Inouts in memory can be either inputs or outputs (if they're addresses being written to). Hence the name.

Primitives usually require their inouts to be in specific combinations of memory and register. They can't handle more than one inout in memory. User-defined functions are flexible.

Primitives can often write to arbitrary output registers. User-defined functions, however, require rigidly specified output registers. Notice how the definition of foo above writes to eax.

A function's header names its inouts, but not its outputs (hence the _ above).

All Mu programs must define at least one function: main. That's where they begin executing instructions.

Variables, registers and memory

Declare local variables in a function using the var keyword. As shown above, all variable declarations should specify a type after a :.

You can declare local variables in either registers or memory (the stack segment). So a var statement has two forms:

  • Living in a register, e.g. var x/eax: int <- copy 0 defines x which lives in eax.
  • Living in memory, e.g. var x: int defines x on the stack.

Variables in registers must be initialized. Variables on the stack are implicitly zeroed out.

Variables exist only within the {} block they're defined in. Space allocated to them on the stack is reclaimed after execution leaves the block. Registers restore whatever variable was using them in the outer block.

It is perfectly ok to reuse a register for a new variable. Even in a single block (though you permanently lose the old variable then).

Variables can be in six 32-bit general-purpose registers of the x86 processor.

  • eax
  • ebx
  • ecx
  • edx
  • esi ('s' often a mnemonic for 'source')
  • edi ('d' often a mnemonic for 'destination')

Most functions return results in eax by convention. In practice, it ends up churning through variables pretty quickly.

You can store several types in these registers:

  • int
  • boolean
  • (addr T) (address into memory)
  • byte (uses only 8 bits)
  • code-point (Unicode)
  • code-point-utf8 (code-point encoded in UTF-8)

There's one 32-bit type you cannot store in these registers:

  • float

It instead uses eight separate 32-bit registers: xmm0, xmm1, ..., xmm7

Types that require more than 32 bits (4 bytes) cannot be stored in registers:

  • (array T)
  • (handle T)
  • (stream T)
  • slice
  • any compound types you define using the type keyword

T here can be any type, including combinations of types. For example:

  • (array int) -- an array of ints
  • (addr int) -- an address to an int
  • (addr array byte) -- an address to an array of bytes, useful for Unicode text strings
  • (handle int) -- a handle to an int
  • (addr handle int) -- an address to a handle to int
  • (addr array handle int) -- an address to an array of handles to ints
  • ...and so on.

Other miscellaneous restrictions:

  • byte variables must be either in registers or on the heap, never local variables on the stack.
  • addr variables can never "escape" a function either by being returned or by being written to a memory location. When you need that sort of thing, use a handle instead.

Operations on simple types

We'll now survey a long list of statement forms that operate on 32-bit types. Most of these are primitives, but some are also implemented as functions (which have slightly different rules as mentioned up top). Most instructions with multiple args require types to match. Various operations have other restrictions which we'll note below, using the following notation:

  • var/reg indicates a variable in some register. Where we require a variable in a specific register, we'll mention it explicitly. E.g. var/eax.
  • var/xreg indicates a variable in some floating-point register xmm_.
  • var without a reg indicates either a variable on the stack, or dereferencing a variable in a (non-floating-point) register: *var/reg.
  • var: type indicates a variable that must satisfy some type constraint.
  • n indicates a literal integer. There are no floating-point literals.

Moving values around

These instructions work with variables of any 32-bit type except byte and float.

  var/reg <- copy var2/reg2
  copy-to var1, var2/reg
  var/reg <- copy var2
  var/reg <- copy n
  copy-to var, n

Byte variables have their own instructions:

  var/reg <- copy-byte var2/reg2
  var/reg <- copy-byte *var2/reg2     # var2 must have type (addr byte)
  copy-byte-to *var1/reg1, var2/reg2  # var1 must have type (addr byte)

Floating point variables can be copied as well, but only to or from floating-point registers xmm_.

  var/xreg <- copy var2/xreg2
  copy-to var1, var2/xreg
  var/xreg <- copy var2
  var/xreg <- copy *var2/reg2         # var2 must have type (addr byte) and live in a general-purpose register

There's no way to copy a literal to a floating-point register. However, there's a few ways to convert non-float values in general-purpose registers.

  var/xreg <- convert var2/reg2
  var/xreg <- convert var2
  var/xreg <- convert *var2/reg2

Correspondingly, there are ways to convert floats into integers, with and without rounding.

  var/reg <- convert var2/xreg2
  var/reg <- convert var2
  var/reg <- convert *var2/reg2

  var/reg <- truncate var2/xreg2
  var/reg <- truncate var2
  var/reg <- truncate *var2/reg2

Still, the absence of fractional literals is an annoyance. Mu provides some helpers to mitigate it somewhat:

  result/xmm0 <- rational numerator: int, denominator: int
  fill-in-rational out: (addr float), numerator: int, denominator: int

These are functions, so the inouts have fewer restrictions while the outputs have more. The inouts can be registers, or memory, or even literals. The output for rational must be in register xmm0.

Comparing values

Work with variables of any 32-bit type. addr variables can only be compared to 0.

  compare var1, var2/reg
  compare var1/reg, var2
  compare var/eax, n
  compare var, n

Floating-point numbers cannot be compared to literals, and the register must come first.

  compare var1/xreg1, var2/xreg2
  compare var1/xreg1, var2

Branches

Immediately after a compare instruction you can branch on its result. For example:

  break-if-=

This instruction will jump to after the enclosing {} block if the previous compare detected equality. Here's the list of conditional and unconditional break instructions:

  break
  break-if-=
  break-if-!=
  break-if-<
  break-if->
  break-if-<=
  break-if->=

Similarly, you can jump back to the start of the enclosing {} block with loop. Here's the list of loop instructions.

  loop
  loop-if-=
  loop-if-!=
  loop-if-<
  loop-if->
  loop-if-<=
  loop-if->=

Additionally, there are special variants for comparing addr and float values, which results in the following comprehensive list of jumps:

  break
  break-if-=
  break-if-!=
  break-if-<    break-if-addr<    break-if-float<
  break-if->    break-if-addr>    break-if-float>
  break-if-<=   break-if-addr<=   break-if-float<=
  break-if->=   break-if-addr>=   break-if-float>=

  loop
  loop-if-=
  loop-if-!=
  loop-if-<     loop-if-addr<     loop-if-float<
  loop-if->     loop-if-addr>     loop-if-float>
  loop-if-<=    loop-if-addr<=    loop-if-float<=
  loop-if->=    loop-if-addr>=    loop-if-float>=

One final property all these jump instructions share: they can take an optional block name to jump to. For example:

  a: {
    ...
    break a     #----------|
    ...               #    |
  }                   # <--|


  a: {                # <--|
    ...               #    |
    b: {              #    |
      ...             #    |
      loop a    #----------|
      ...
    }
    ...
  }

However, there's no way to jump to a block that doesn't contain the loop or break instruction.

Integer arithmetic

These instructions require variables of non-addr, non-float types.

Add:

  var1/reg1 <- add var2/reg2
  var1/reg <- add var2
  add-to var1, var2/reg                 # var1 += var2
  var/reg <- add n
  add-to var, n

Subtract:

  var1/reg1 <- subtract var2/reg2
  var1/reg <- subtract var2
  subtract-from var1, var2/reg          # var1 -= var2
  var/reg <- subtract n
  subtract-from var, n

Add one:

  var/reg <- increment
  increment var

Subtract one:

  var/reg <- decrement
  decrement var

Multiply:

  var1/reg <- multiply var2

The result of a multiply must be a register.

Negate:

  var/reg1 <- negate
  negate var

Fractional arithmetic

Operations on float variables include a few we've seen before and some new ones. Notice here that we mostly use floating-point registers xmm_, but still use the general-purpose registers when dereferencing variables of type (addr float).

  var1/xreg <- add var2/xreg2
  var1/xreg <- add var2
  var1/xreg <- add *var2/reg2

  var1/xreg <- subtract var2/xreg2
  var1/xreg <- subtract var2
  var1/xreg <- subtract *var2/reg2

  var1/xreg <- multiply var2/xreg2
  var1/xreg <- multiply var2
  var1/xreg <- multiply *var2/reg2

  var1/xreg <- divide var2/xreg2
  var1/xreg <- divide var2
  var1/xreg <- divide *var2/reg2

  var1/xreg <- reciprocal var2/xreg2
  var1/xreg <- reciprocal var2
  var1/xreg <- reciprocal *var2/reg2

  var1/xreg <- square-root var2/xreg2
  var1/xreg <- square-root var2
  var1/xreg <- square-root *var2/reg2

  var1/xreg <- inverse-square-root var2/xreg2
  var1/xreg <- inverse-square-root var2
  var1/xreg <- inverse-square-root *var2/reg2

  var1/xreg <- min var2/xreg2
  var1/xreg <- min var2
  var1/xreg <- min *var2/reg2

  var1/xreg <- max var2/xreg2
  var1/xreg <- max var2
  var1/xreg <- max *var2/reg2

Two instructions in the above list are approximate. According to the Intel manual, reciprocal and inverse-square-root go off the rails around the fourth decimal place. If you need more precision, use divide separately.

Bitwise boolean operations

These require variables of non-addr, non-float types.

And:

  var1/reg1 <- and var2/reg2
  var1/reg <- and var2
  and-with var1, var2/reg
  var/reg <- and n
  and-with var, n

Or:

  var1/reg1 <- or var2/reg2
  var1/reg <- or var2
  or-with var1, var2/reg
  var/reg <- or n
  or-with var, n

Not:

  var1/reg1 <- not
  not var

Xor:

  var1/reg1 <- xor var2/reg2
  var1/reg <- xor var2
  xor-with var1, var2/reg
  var/reg <- xor n
  xor-with var, n

Bitwise shifts

Shifts require variables of non-addr, non-float types.

  var/reg <- shift-left n
  var/reg <- shift-right n
  var/reg <- shift-right-signed n
  shift-left var, n
  shift-right var, n
  shift-right-signed var, n

Shifting bits left always inserts zeros on the right. Shifting bits right inserts zeros on the left by default. A signed shift right duplicates the leftmost bit, thereby preserving the sign of an integer.

Operations on more complex types

These instructions work with any type T. As before we use /reg here to indicate when a variable must live in a register. We also include type constraints after a :.

Addresses and handles

You can compute the address of any variable in memory (never in registers):

  var1/reg: (addr T) <- address var2: T

As mentioned up top, addr variables can never escape the function where they're computed. You can't store them on the heap, or in compound types. Think of them as short-lived things.

To manage long-lived addresses, allocate them on the heap.

  allocate var: (addr handle T)       # var can be in either register or memory

Handles can be copied and stored without restriction. However, they're too large to fit in a register. You also can't access their payload directly, you have to first convert them into a short-lived addr using lookup.

  var1/eax: (addr T) <- lookup var2: (handle T)  # var2 in either register or memory

Since handles are large compound types, there's a special helper for comparing them:

  var/eax: boolean <- handle-equal? var1: (handle T), var2: (handle T)

Arrays

Arrays are declared in two ways:

  1. On the stack with a literal size:
  var x: (array int 3)
  1. On the heap with a potentially variable size. For example:
  var x: (handle array int)
  var x-ah/eax: (addr handle array int) <- address x
  populate x-ah, 8

The 8 here can also be an int in a register or memory. (The -ah is a common variable naming convention and stands for "address of a handle". Essential for allocating long-lived data on the heap.)

You can compute the length of an array, though you'll need an addr to do so:

  var/reg: int <- length arr/reg: (addr array T)

To read from or write to an array, use index to first obtain an address to read from or modify:

  var/reg: (addr T) <- index arr/reg: (addr array T), n
  var/reg: (addr T) <- index arr: (array T len), n

Like our notation of n, len here is required to be a literal.

The index requested can also be a variable in a register, with one caveat:

  var/reg: (addr T) <- index arr/reg: (addr array T), idx/reg: int
  var/reg: (addr T) <- index arr: (array T len), idx/reg: int

The caveat: the size of T must be 1, 2, 4 or 8 bytes. For other sizes of T you'll need to split up the work, performing a compute-offset before the index.

  var/reg: (offset T) <- compute-offset arr: (addr array T), idx/reg: int     # arr can be in reg or mem
  var/reg: (offset T) <- compute-offset arr: (addr array T), idx: int         # arr can be in reg or mem

The result of a compute-offset statement can be passed to index:

  var/reg: (addr T) <- index arr/reg: (addr array T), idx/reg: (offset T)

Streams

A common use for arrays is as buffers. Save a few items to a scratch space and then process them. This pattern is so common (we use it in files) that there's special support for it with a built-in type: stream.

Streams are like arrays in many ways. You can initialize them with a length on the stack:

  var x: (stream int 3)

You can also populate them on the heap:

  var x: (handle stream int)
  var x-ah/eax: (addr handle stream int) <- address x
  populate-stream x-ah, 8

However, streams don't provide random access with an index instruction. Instead, you write to them sequentially, and read back what you wrote.

  read-from-stream s: (addr stream T), out: (addr T)
  write-to-stream s: (addr stream T), in: (addr T)

Streams of bytes are particularly common for managing Unicode text, and there are a few functions to help with them:

  write s: (addr stream byte), u: (addr array byte)  # write u to s, abort if full
  overflow?/eax: boolean <- try-write s: (addr stream byte), u: (addr array byte)
  write-stream dest: (addr stream byte), src: (addr stream byte)
  # bytes
  append-byte s: (addr stream byte), var: int  # write lower byte of var
  var/eax: byte <- read-byte s: (addr stream byte)
  # 32-bit code-point-utf8s encoded in UTF-8
  write-code-point-utf8 out: (addr stream byte), g: code-point-utf8
  g/eax: code-point-utf8 <- read-code-point-utf8 in: (addr stream byte)

You can check if a stream is empty or full:

  var/eax: boolean <- stream-empty? s: (addr stream)
  var/eax: boolean <- stream-full? s: (addr stream)

You can clear streams:

  clear-stream f: (addr stream T)

You can also rewind them to reread their contents:

  rewind-stream f: (addr stream T)

Compound types

Primitive types can be combined together using the type keyword. For example:

type point {
  x: int
  y: int
}

Mu programs are sequences of just fn and type definitions.

Compound types can't include addr types for safety reasons (use handle instead, which is described below). They also can't currently include array, stream or byte types. Since arrays and streams carry their size with them, supporting them in compound types complicates variable initialization. Instead of defining them inline in a type definition, define a handle to them. Bytes shouldn't be used for anything but UTF-8 strings.

To access within a compound type, use the get instruction. There are two forms. You need either a variable of the type itself (say T) in memory, or a variable of type (addr T) in a register.

var/reg: (addr T_f) <- get var/reg: (addr T), f
var/reg: (addr T_f) <- get var: T, f

The f here is the field name from the type definition, and its type T_f must match the type of f in the type definition. For example, some legal instructions for the definition of point above:

var a/eax: (addr int) <- get p, x
var a/eax: (addr int) <- get p, y

You can clear compound types using the clear-object function:

clear-object var: (addr T)

You can shallow-copy compound types using the copy-object function:

copy-object src: (addr T), dest: (addr T)