Technical Specification

Warning This documentation is a template and shall be updated with your own APDUs.

About

This documentation describes the APDU messages interface to communicate with the Boilerplate application.

The application covers the following functionalities :

  • Get a public Boilerplate address given a BIP 32 path
  • Sign a basic Boilerplate transaction given a BIP 32 path and raw transaction
  • Retrieve the Boilerplate app version
  • Retrieve the Boilerplate app name

The application interface can be accessed over HID or BLE

APDUs

GET BOILERPLATE PUBLIC ADDRESS

Description

This command returns the public key for the given BIP 32 path.

The address can be optionally checked on the device before being returned.

Coding

Command
CLA INS P1 P2 Lc Le
E0 05 00 : return address 00 variable variable
01 : display address and confirm before returning
Input data
Description Length
Number of BIP 32 derivations to perform (max 10) 1
First derivation index (big endian) 4
... 4
Last derivation index (big endian) 4
Output data
Description Length
Public Key length 1
Public Key var
Chain code length 1
Chain code var

SIGN BOILERPLATE TRANSACTION

Description

This command signs a Boilerplate transaction after having the user validate the transactions parameters.

The input data is the RLP encoded transaction streamed to the device in 255 bytes maximum data chunks.

Coding

Command
CLA INS P1 P2 Lc Le
E0 06 00-FF : chunk index 00 : last transaction data block variable variable
80 : subsequent transaction data block
Input data (first transaction data block)
Description Length
Number of BIP 32 derivations to perform (max 10) 1
First derivation index (big endian) 4
... 4
Last derivation index (big endian) 4
Input data (other transaction data block)
Description Length
Transaction chunk variable
Output data
Description Length
Signature length 1
Signature variable
v 1

GET APP VERSION

Description

This command returns boilerplate application version

Coding

Command
CLA INS P1 P2 Lc Le
E0 03 00 00 00 04
Input data

None

Output data
Description Length
Application major version 01
Application minor version 01
Application patch version 01

GET APP NAME

Description

This command returns boilerplate application name

Coding

Command
CLA INS P1 P2 Lc Le
E0 04 00 00 00 04
Input data

None

Output data
Description Length
Application name variable

Status Words

The following standard Status Words are returned for all APDUs.

Status Words
SW SW name Description
6985 SW_DENY Rejected by user
6A86 SW_WRONG_P1P2 Either P1 or P2 is incorrect
6A87 SW_WRONG_DATA_LENGTH Lc or minimum APDU length is incorrect
6D00 SW_INS_NOT_SUPPORTED No command exists with INS
6E00 SW_CLA_NOT_SUPPORTED Bad CLA used for this application
B000 SW_WRONG_RESPONSE_LENGTH Wrong response length (buffer size problem)
B001 SW_DISPLAY_BIP32_PATH_FAIL BIP32 path conversion to string failed
B002 SW_DISPLAY_ADDRESS_FAIL Address conversion to string failed
B003 SW_DISPLAY_AMOUNT_FAIL Amount conversion to string failed
B004 SW_WRONG_TX_LENGTH Wrong raw transaction length
B005 SW_TX_PARSING_FAIL Failed to parse raw transaction
B006 SW_TX_HASH_FAIL Failed to compute hash digest of raw transaction
B007 SW_BAD_STATE Security issue with bad state
B008 SW_SIGNATURE_FAIL Signature of raw transaction failed
9000 OK Success