Skip to content

This daemon is to calculate and update margin temperatures for fan PID control . The margin temperatures are updated one by one with 1 second interval between each zone. The unit of margin temperature is millidegree.

License

Notifications You must be signed in to change notification settings

Krellan/read-margin-temp

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

93 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

read-margin-temp

This daemon is to calculate and update margin temperatures for fan PID control.

At 1 second intervals, all input sensors are read, and for each thermal zone, the combined worst margin is calculated and output. The input source type (dbus, sys, file) and measurement unit (millidegree, degree, millimargin, margin) are configurable, for each input sensor.

After reading all input sensors, and converting units as necessary, the combined worst margin will be output. The output type is dbus, and the output unit is margin (degrees of thermal safety margin).

This daemon will check sensor threshold and functional dbus property. If functional dbus is false, which means driver is not update value to dbus, it will set NaN to sensor dbus value.

Configuration File

The configuration file has "sensors" and "skus" parts.
The "sensors" part contains all the information of sensors, including paths for temperature reading and paths for max temperature. The "skus" part has the list of all sku configurations.
The detailed introduction is listed below.

Sensor Configuration

  • "sensors" : [
    • {
      • "name": "cpu0", /* name of the sensor */
      • "unit": "millidegree", /* temperature unit: millidegree, degree, millimargin, margin */
      • "type": "dbus", /* temperature reading path type: dbus, sys, file */
      • "path": "/xyz/openbmc_project/sensors/temperature/cpu0", /* temperature reading dbus or sys path */
      • "parameters": {
        • "type": "sys", /* max temperature reading type: sys, file */
        • "maxTemp": -1, /* fixed max temperature, -1 for not fixed, unit: millidegree */
        • "path": "/sys/devices/platform/ahb/ahb:apb/f0100000.peci-bus/peci-0/0-30/peci-cputemp.0/hwmon", /* max temperature reading /sys/devices path */
        • "sysLabel": "Tjmax", /* if sys, hwmon label for finding hwmon input file */
        • "targetTemp": -1, /* calibration target temperature, unit: millidegree */
        • "targetTempOffset": -10000, /* calibration target temperature's offset, unit: millidegree */
        • "scalar": 1.0 /* scalar value */
      • }
    • }
  • ]

Sku Configuration

  • "skus" : [
    • {
      • "num": 1, /* sku number */
      • "zones": [
        • {
          • "id": 0, /* zone id */
          • "zoneSetpoint": 10000, /* zone setpoint, unit: millimargin */
          • "target": "/xyz/openbmc_project/extsensors/margin/real_fleeting0", /* target dbus path */
          • "components": ["cpu0", "dimm1"] /* sensor names list */
        • },
        • {
          • "id": 1, /* zone id */
          • "zoneSetpoint": 10000, /* zone setpoint, unit: millimargin */
          • "target": "/xyz/openbmc_project/extsensors/margin/real_fleeting1", /* target dbus path */
          • "components": ["cpu1", "dimm2"] /* sensor names list */
        • }
      • ]
    • }
  • ]

About

This daemon is to calculate and update margin temperatures for fan PID control . The margin temperatures are updated one by one with 1 second interval between each zone. The unit of margin temperature is millidegree.

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • C++ 98.3%